Permit Information
Permit NumberELE20-00064
StatusFinaled
Name BOBS 208 ELECTRIC LLC
Site Address 1414 E WASHINGTON ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: replace fuse box, rewire kitchen, flood damage
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/14/20207/14/20207/14/2020APASS
DetailsJames Ady
homeowner working from home Phone #: ###-#### Inspection requested via web by Dale Johnson Kitchen walls were not open at rough in and kitchen layout did not change. Added recep on cabinet face do not meat code, but could not be added in wall without causing damage. Final ok
Electrical Rough-In1/17/20201/17/20201/17/2020APASS
DetailsJames Ady
between 8:00 and 10:00 if possible, subpanel rough-in inspection, Bob ###-#### Phone #: ###-#### Inspection requested via web by Dale Johnson Panel wall in back mud room/ laundry room only. All other additions will be cut in or surface mount
Conference1/13/20201/13/20201/13/2020APASS
DetailsJames Ady
need a consult on service upgrade, would appreciate earlier inspection 8:00-10:00, bob ###-#### Phone #: ###-#### Inspection requested via web by Dale Johnson Discussed Changing fuse box to 100A panel. Existing service ok. No main breaker but less than 6 throws. Check grounding. Up date Range plug and cord. 3wire in conduit with insulated nuetral.