Permit Information
Permit NumberELE20-00730
StatusFinaled
Name POND TYLER G
Site Address 10606 W CRUSER DR
Project NamePond Home
Customer Number 
ePlanReviewNo
Description
Complete installation
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/4/20208/4/20208/4/2020PPASS
DetailsDaryl DeGrange
Screened-Tyler Phone #: ###-#### corrections complete, final ok
Final8/3/20208/4/20208/4/2020AFAIL
DetailsDaryl DeGrange
ok with video/photo // Tyler Phone #: ###-#### NEC 406.9 Receptacles shall not be installed within or directly over a bathtub or shower stall.
NEC 300.5 Underground installations, conduit or other raceways shall be installed to meet the minimum cover requirement of 12 in. for 120 volt GFCI protected. 6in. minimum cover for 30 volts or less
Final8/3/20208/3/20208/3/2020PFAIL
DetailsDaryl DeGrange
Not living in home // Tyler Phone #: ###-#### NEC 210.8(A)(2) All 120 volt, single phase, 15 and 20 amp receptacles installed garages shall be GFCI portected, outlet near furnace.
NEC 210.8(A)(3) All120 volt, single phase, 15 and 20 amp receptacles installed outdoors shall be GFCI protected, front porch.
NEC 406.12 All 15 and 20 ampere 120 and 250 volt nonlocking-type receptacles in dwelling units require Tamper Resistanted Receptacles.
NEC 352.30(A) PVC conduit shall be securely fastened within 3 ft. service meter base.
Conference7/13/20207/13/20207/13/2020PPASS
DetailsTom Saunders
new build .. SCREENED // Tyler Phone #: ###-####...discussed wiring of island receptacles...1 per island to meet requirement
Electrical Rough-In4/9/20204/10/20204/10/2020ACANC
DetailsTom Saunders
screened // Tyler Phone #: ###-####...needed rough perm service...scheduled and resulted
Rough-In Permanent Service4/10/20204/10/20204/10/2020APASS
DetailsTom Saunders
screened // Tyler Phone #: ###-####...
rough in ok to cover
p/s u/g new ok
Electrical Rough-In4/8/20204/8/20204/8/2020PCANC
DetailsTom Saunders
Tyler **Cleared** Phone #: ###-####...not ready...needed conference
Conference4/8/20204/8/20204/8/2020PPASS
DetailsTom Saunders
Tyler **Cleared** Phone #: ###-####...
discussed, make up of outlet and switches, GFCI requirement for all receptacles in bathrooms, powering of SD, dining rm circuit requirement, expansion joint at service required to be expanded halfway, 8/3 at panel needs proper connector-not B/A glued to coupling-needs positive crimp on wire, recessed can lighting junction boxes installed at first location of all rooms with recessed can lighting, hot tub wiring completed to exterior both ends
Conference3/2/20203/2/20203/2/2020PDONE
DetailsMark Moncarr
Discussed service requirements and layout of house. Dedicated circuits. wall spacing etc. Homeowner has a grasp on what he is doing. Call me Tom with any questions.
Final3/2/20203/2/20203/2/2020PCANC
DetailsMark Moncarr
Tyler Phone #: ###-#### Changed to a conference.