Permit Information
Permit NumberELE20-02151
StatusIssued
Name REAL POWER CONSTRUCTION LLC
Site Address 444 W BOISE AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Remodel
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Electrical Rough-In7/22/20207/23/20207/23/2020APASS
DetailsJames Ady
Units 448 and 450 only Phone #: ###-#### Inspection requested via web by Ben Grundhauser Units 448 and 450 only ok to cover
Electrical Rough-In7/13/20207/13/20207/13/2020PPASS
DetailsJames Ady
Reinspection of Units 444 and 446 only Phone #: ###-#### Inspection requested via web by Ben Grundhauser corrections made rough in ok
Electrical Rough-In7/5/20207/7/20207/7/2020AFAIL
DetailsJames Ady
Units 444 and 446 ONLY are ready for rough/remodel inspection Phone #: ###-#### Inspection requested via web by Ben Grundhauser 210.11C2 and C3. 20A laundry circuit shall have no other outlets, 20A Bath circuit shall have no other outlets. ( Seperate washer and Bath circuit, add circuit for Bath vanity.) At final Bed shall be AFCI protected, J-box in closet of 444 and 446 shall be blanked with no device installed as it is part of the kitchen/ dining room circuit.