Site Final | 3/23/2017 | 3/23/2017 | 3/23/2017 | A | PASS |
Andy J. Long
|
|
|
Subdivsion fully developed and stabilized. Site permanent stormwater swales and infiltration pond are operational. Common areas landscaped. All homes complete and most occupied. Damage filter fabric in inlets on Elmbrook to be removed by HOA.
|
General Inspection | 3/10/2017 | 3/10/2017 | 3/10/2017 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 1/23/2017 | 1/23/2017 | 1/23/2017 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 12/6/2016 | 12/6/2016 | 12/6/2016 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 10/21/2016 | 10/21/2016 | 10/21/2016 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 9/5/2016 | 9/5/2016 | 9/5/2016 | | CANC |
Evan Jenkins
|
|
|
holiday
|
General Inspection | 7/21/2016 | 7/21/2016 | 7/21/2016 | P | PASS |
Evan Jenkins
|
|
|
work occuring on various SFH's. No issues observed at this time
|
General Inspection | 6/24/2016 | 6/24/2016 | 6/24/2016 | | PASS |
Evan Jenkins
|
|
|
No issues observed at this time
|
BMP Violation | 5/9/2016 | 5/9/2016 | 5/9/2016 | A | FAIL |
Andy J. Long
|
|
|
No lined concrete washout provided.
Correction request to builders and developer to provide a lined and designated concrete washout pit.
Check storm drain inlets for DI bag maintenance.
|
General Inspection | 5/3/2016 | 5/3/2016 | 5/3/2016 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 3/18/2016 | 3/18/2016 | 3/18/2016 | | PASS |
Evan Jenkins
|
|
|
sfh construction occuring. no issues observed at this time
|
General Inspection | 2/1/2016 | 2/1/2016 | 2/1/2016 | | PASS |
Evan Jenkins
|
|
|
WIP: No ESC Violations observed at this time
|
Random Inspection | 12/16/2015 | 12/16/2015 | 12/16/2015 | P | PASS |
Andy J. Long
|
|
|
WIP on SFHs in Magnolia Park (formerly Fairmont Square). No sediment runoff from open lots. Permanent stormwater facilities are working properly and no discharges offsite. Builders parking on street to prevent trackout.
No corrections at this time
|
General Inspection | 11/16/2015 | 11/16/2015 | 11/16/2015 | | PASS |
Andy J. Long
|
|
|
WIP on SFHs in Fairmont Square. Permanent stormwater controls and subdivision landscaping are complete. No erosion issues observed of drainage failures.
Home builders are keeping off open lots, no major trackout or loose sediment. Trash containment is provided. No spills or discharges observed. Approved.
|
General Inspection | 9/30/2015 | 9/30/2015 | 9/30/2015 | | PASS |
Andy J. Long
|
|
|
Subdivision work complete. 2 SFHs in progress. DIs have inlet protection. No trackout, discharges, or uncontained trash observed. No corrections.
|
General Inspection | 8/14/2015 | 8/14/2015 | 8/14/2015 | | PASS |
Evan Jenkins
|
|
|
|
Aging Inspection | 6/26/2015 | 6/26/2015 | 6/26/2015 | | PART |
Andy J. Long
|
|
|
WIP on storm drain and irrigation infrastructure. No SFH work yet at Fairmont Square. Some trackout within site but not to Bogart or Caswell. No fugitive dust observed.
Did not see permit sign or NOI information. Will check with contractor. Subdivision was built mostly prior to being annexed by Boise in late 2014.
|
Complaint Inspection | 2/27/2015 | 2/27/2015 | 2/27/2015 | P | PART |
Evan Jenkins
|
|
|
Per ACHD: Dewatering is taking place, traveling through silt fence and down ditch. Extremely turbid water. Also, a site prep inspection was required, which was not called in Contractor has 3 settling ponds set up that they are discharging into. Due to the high level of groundwater, pumped water doesn't have enough time of settle out before discharging into a ditch. Correction: 1.) Set primary well point to draw down groundwater level 2.) Place 5 clean gravel check dams inside the ditch to slow velocity and aid sediment drop out. Contractor began making changing immediately
|