Permit Information
Permit NumberESC17-01298
StatusFinaled
Name CLINT WALL
Site Address 6833 E WARM SPRINGS AVE
Project NameRidgeway A
Customer Number 
ePlanReviewNo
Description
Single family dwelling
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Aging Inspection12/25/201812/25/201812/26/2018 CANC
DetailsMichael Zawacki
DOC - Permit Finaled12/26/201812/26/201812/26/2018PPASS
DetailsMichael Zawacki
Aging Inspection10/24/201810/24/201810/24/2018 PASS
DetailsMichael Zawacki
No ESC issues. Lots of activity in site.
General Inspection8/24/20188/24/20188/24/2018APASS
DetailsMichael Zawacki
check backyard & slope behind fence to greenbelt; should have wattle if not landscaped.
Wattle installed along rear of lot and on hillside above greenbelt.
General Inspection6/22/20186/25/20186/25/2018APART
DetailsAndy J. Long
Wattles are now trenched and staked in at proper intervals as requested.

The overlaps have been installed on top of each other rather than side by side, leaving a gap in wattle perimeter.

Notified Mike with Provision landscaping of the change needed.
General Inspection6/20/20186/22/20186/22/2018PPEND
DetailsAndy J. Long
follow up on wattle installation

Mike with Provision Landscaped called to notify that wattles had been re-installed per specifications. Will check up later today or Monday AM.
Conference6/19/20186/20/20186/20/2018ADONE
DetailsAndy J. Long
Meeting with Mike with Proscape Landscaping (208.514.7457) to provide training and BMP flip guide on wattle installation.

Meeting with Mike with ProVision Landscaping (208.514.7457) to provide training and BMP flipguide on wattle installation. 9 AM

required installation specifications:
- 8 " wattle
- set wattle in 2-3" deep half circle trench along countour/perimeter (within 1 ft of fence line)
- stake wattles at ends and at 4-5 intervals in between. Adjoining sections should be overlapped 6" and staked tightly together
- backfill trench dirt on upslope side of wattle

Provided BMP booklet and RP manual. Mike will enroll in class as well

Follow up scheduled Friday 6/22 PM
General Inspection6/14/20186/15/20186/18/2018APART
DetailsAndy J. Long
follow up to check on perimeter wattle installation

Wattle is now installed along back fence as requested.

Wattle installed not per specifications. No trench. No overlap or tight butting.

General Inspection6/8/20186/12/20186/12/2018PFAIL
DetailsAndy J. Long
follow up

No wattles installed as requested. No change in grading or notification of change in landscaping.

Second correction request to Clint. Need to install before the end of the week.
General Inspection6/8/20186/8/20186/8/2018PFAIL
DetailsAndy J. Long
Backfill from foundations pushed to rear of lot. No perimeter control for sediment and earthen berm that was installed to prevent water from going down slope has been graded over.

Correction request to Clint to re-grade berm and install wattle at bottom of subdivision fence.