Permit Information
Permit NumberESC18-01455
StatusIssued
Name JOHN CLONINGER
Site Address 3550 N WINSOME RD
Project NameJohnson Residence
Customer Number 
ePlanReviewNo
Description
Construction of 2-Story Residence
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection8/6/20208/6/20208/6/2020 PASS
DetailsMichael Zawacki
Site is contained. Some dust on driveway when worker left.
General Inspection7/22/20207/22/20207/22/2020 CANC
DetailsAndy J. Long
General Inspection7/7/20207/7/20207/9/2020 PASS
DetailsMichael Zawacki
Site is clean and contained. Entrance in good shape, no tracking.
General Inspection6/22/20206/22/20206/22/2020 PASS
DetailsMichael Zawacki
Lot is clean, entrance in good shape, no tracking. Hillside is heavily vegetated.
General Inspection6/5/20206/5/20206/8/2020 PASS
DetailsMichael Zawacki
RP is on site.
Looks like rock entrance has been extended, no tracking. Hillside is covered in vegetation.
General Inspection5/21/20205/21/20205/21/2020 PASS
DetailsMichael Zawacki
Lot contained. No issues, no tracking.
General Inspection5/6/20205/6/20205/6/2020 PASS
DetailsMichael Zawacki
RPC on site. Lot is vegetated and contained. RP is at site. No issues.
General Inspection4/21/20204/21/20204/21/2020 PASS
DetailsMichael Zawacki
Hillside vegetated. No issues with site. RP on site daily.
General Inspection4/6/20204/6/20204/6/2020 PASS
DetailsAndy J. Long
No trackout or sediment runoff. WIP on home. No requests at this time.
General Inspection3/20/20203/20/20203/20/2020 CANC
DetailsAndy J. Long
General Inspection3/4/20203/4/20203/5/2020 PASS
DetailsMichael Zawacki
Lot clean and conjtained. No trackout from driveway.
General Inspection2/18/20202/18/20202/19/2020 PART
DetailsMichael Zawacki
Some trackout from driveway. RP is aware.
General Inspection2/3/20202/3/20202/3/2020 PASS
DetailsMichael Zawacki
Site is cleasn. Tracking has been swept up.
General Inspection1/17/20201/17/20201/17/2020 PASS
DetailsMichael Zawacki
All contained, gate now at base of driveway.
General Inspection1/1/20201/1/20201/3/2020 PASS
DetailsAndy J. Long
No runoff or new erosion issues observed
General Inspection12/17/201912/17/201912/17/2019 PASS
DetailsAndy J. Long
No trackout. No sediment runoff observed. No corrections at this time
General Inspection12/2/201912/2/201912/2/2019 PASS
DetailsMichael Zawacki
No trackout, no esc issues.
General Inspection11/15/201911/15/201911/15/2019 PASS
DetailsAndy J. Long
General Inspection10/31/201910/31/201911/1/2019 PASS
DetailsMichael Zawacki
Site is contained, hillsides have vegetation. No trackout or rocks on road.
General Inspection10/11/201910/16/201910/17/2019APASS
DetailsMichael Zawacki
Lot is contained. No runoff or trackout.
General Inspection10/10/201910/10/201910/11/2019 CANC
DetailsAndy J. Long
General Inspection9/25/20199/25/20199/25/2019 PASS
DetailsMichael Zawacki
Met with RP John on site. Area is clean, no loose or blowing trash, bins on site. Good vegetation and ponds on lot, should handle all water. No rocks being tracked out.
General Inspection8/30/20198/30/20198/30/2019 PASS
DetailsMichael Zawacki
Hillside leading up to home is all vegetated. Driveway is gravel, has water bars to direct to retention ponds.
General Inspection8/13/20198/14/20198/19/2019PPART
DetailsAndy J. Long
Needs maintenance on construction entrance.
General Inspection8/8/20198/8/20198/13/2019 CANC
DetailsAndy J. Long
General Inspection5/22/20195/22/20195/22/2019PFAIL
DetailsAndy J. Long
No significant trackout. Runoff contained within ponds, slopes are vegetated.

Dumped/spilled concrete washout next to the Ecopan.

Clean up washout. Provide level surface for the EcoPan, and consider covering with a tarp for forecasted rain.

Verbal correction to RP John
General Inspection3/12/20193/12/20193/12/2019PFAIL
DetailsAndy J. Long
Corrections needed:

? full concrete washout next to private driveway needs removal and/or replacement. Placement is not indicated on site specific ESC map nor the subdivision ESC map.
? “Protective Berm” drawn in green is not installed as drawn.
? Upper pond, pond #2 is not shown on map and has some erosion from runoff from the private drive.
? Lower water bar for pond #2 needs to be rebuilt/improved to capture sheet flow from private drive.
? Water bar for pond #3 needs to be rebuilt/improved to capture sheet flow from private drive.
? Runoff from the private drive is running off road at curve around pond #2 and down slope towards the culdesac. Wattle installed mid slope needs maintenance, re-trenching and staking, rill should be raked and tracked. Runoff should be directed into pond #2 as shown on drainage plan
? Construction entrance should measure 50 ft. in length as listed in ESC site map.

Corrections due 3/22/2019. Inspection report emailed to RP and owner.

Conference2/14/20192/14/20192/15/2019PFAIL
DetailsAndy J. Long
see ESC17-00954
Site Preparation1/8/20191/8/20191/8/2019PPASS
DetailsMichael Zawacki
check to see if any work has started. No site prep scheduled.
No work has begun. RP on site, all BMPs from grading still in place.