Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberESC18-01735
StatusFinaled
Name RUSTY L YOUNG
Site Address 500 S WALNUT ST
Project NameKristen Armstrong riverbank Re
Customer Number 
ePlanReviewNo
Description
see also CFH18-00101 for documents and approvals for river system and flood plain work. Riverbank repair project including removal of unsuitable material, placement of fill and rip rap, and erosion prevention and stabilization measures of geotextile fabric and revegetative plantings (willow cuttings). Site will need a stabilized entrance or other method to protect existing grass and prevent trackout of mud. ESC plan calls for turbidity curtain installation around the project area. Fabric ECBs must be installed per manufacturer specifications. Site Preparation inspection required at beginning of project.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final4/4/20194/5/20194/5/2019PPASS
DetailsAndy J. Long
Work complete, area stabilized. Approved.
General Inspection1/22/20191/22/20191/23/2019PPASS
DetailsMichael Zawacki
Rockwork and channel armoring completed. Willows have been planted. Fill being placed and compacted on slopes, will all be landscaped. Backfill materials stored in park.
General Inspection1/7/20191/7/20191/11/2019PPASS
DetailsAndy J. Long
no construction activity yet. Equipment staged in parking lot.
Site Preparation12/24/201812/26/201812/27/2018ADEFR
DetailsMichael Zawacki
Left message with contractor. Stopped by location and didn't see any equipment or work.
Site Preparation12/24/201812/24/201812/24/2018PCANC
DetailsAndy J. Long
RP called to notify construction is to begin on Wednesday
Site Preparation12/18/201812/18/201812/18/2018PPEND
DetailsAndy J. Long
Pre-construciton site meeting conducted last week. Work has not yet started. RP Rusty to notify when BMPs are installed.