INSP-Final Inspection | 10/31/2005 | 10/31/2005 | 10/31/2005 | P | PASS |
Troy Cobbley
|
|
|
Fire alarm permit finaled
|
FIR-Aging Inspection | 10/24/2005 | 10/24/2005 | 10/31/2005 | | PASS |
Troy Cobbley
|
|
|
permit finaled
|
FIR-Aging Inspection | 7/28/2005 | 7/28/2005 | 8/1/2005 | | NR |
Troy Cobbley
|
|
|
Per Brian with AIC he will contact the owner again to provide the knox key box.
|
INSP-Conference | 5/26/2005 | 5/26/2005 | 5/26/2005 | P | DONE |
Troy Cobbley
|
|
|
I spoke to Brian with AIC Solutions and let him know that all that is needed is the Knox Key box.
|
FIR-Aging Inspection | 4/6/2005 | 4/6/2005 | 4/6/2005 | P | PEND |
Forrest France
|
|
|
I called Brian with AIC solutions, ###-####, and left a message on his voice mail requesting status of the fire alarm installation
|
INSP-Final Inspection | 2/4/2005 | 2/4/2005 | 2/4/2005 | P | FAIL |
Troy Cobbley
|
|
|
Provide knox key box. The tamper switches for the backflow preventor did not annunciate separately from the other tamper switch as required by IFC 903.4.1. Need record of completion nfpa form at final. 2/4/2005 3:16:57 PM
|
INSP-Final Inspection | 12/16/2004 | 12/17/2004 | 12/17/2004 | P | FAIL |
Troy Cobbley
|
|
|
Battery calcs, flow switch, battery supervision and smoke detectors on the east side of building (5 total) operate correctly. Inspection stopped after finding the items listed. The monitoring company is not getting all of the signals sent such as Phone line 1 and low battery. Smoke detectors on the west half of the building annunciate locally but do not report to the panel. The tamper switches supervisory signal is latching and is not supposed to per nfpa 72 4.4.3.2.4. Per the manufacturer the panel can't be reprogrammed. 12/17/2004 1:56:55 PM
|
INSP-Final Inspection | 11/16/2004 | 11/17/2004 | 11/17/2004 | P | CANC |
Troy Cobbley
|
|
|
A new fire alarm panel has been installed. Contractor needs to resubmit plans for plan modifications 11/17/2004 3:45:38 PM
|
INSP-Final Inspection | 10/25/2004 | 10/25/2004 | 10/25/2004 | P | FAIL |
Troy Cobbley
|
|
|
Inspection was stopped due to so many items being incorrect. Phone lines are not being supervised. Smoke detector installed is not the one submitted. Supervisory signal latches. No map of initiating devices. Need zone description at annunciator. No one to test the new tamper switches. Strobe does not work.
|
INSP-Conference | 3/9/2004 | 3/9/2004 | 3/9/2004 | A | DONE |
Troy Cobbley
|
|
|
Odie with Steed Construction called wanting to know the status of the fire alarm drawings. I quoted the history.
|
INSP-Conference | 3/3/2004 | 3/3/2004 | 3/3/2004 | A | DONE |
Troy Cobbley
|
|
|
At Mary's request I stopped at this project to verify if smoke detectors are installed and if possible the reason they are installed. I found smoke detectors installed on the left hand side of the lobby at three fire doors and what appears to be area coverage through out the office area to the right of the lobby. The smoke detectors at the fire doors are mounted on the walls on the lobby side and appear to exceed 12" down from the ceiling
|