Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberFIR05-00710
StatusFinaled
Name IDAHO FIRE PROTECTION
Site Address 2907 W CANAL ST
Project NameSPR JEMS TRIPLEX BLDG #4
Customer Number 
ePlanReview 
Description
(JEMS PROPERTIES TRIPLEX BUILDING #4 - APT #101, 201, 301) To install a fire life safety NFPA 13R system to prevent flashover (total involvement) in the room of fire origin, where sprinklered, and to improve the chance for occupants to escape/evacuated required for building "story" increase per the 2000 IBC, in a new 3,375-ft/2 three story, triplex. This work does not include the underground supply. Separate permit required for fire service underground with multiple lead-in work. The first floor is two bedrooms and two baths, at 1,186-ft/2, the second floor is two bedrooms and two baths with a 1,186-ft/2 and the third floor is one bedroom and one bath with 816-ft/2. System shall be equipped with an alarm initiating device connected to an alarm system and an outside annunciating devise. All fire sprinkler work and related, which includes dual service underground water supply, the system backflow prevention device (provided by others), shall be per NFPA 13R, approved plans, engineering/red-lining and attached review comments, under direction of the Fire Chief. This permit is attached to: BLD05-00806.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection1/9/20071/9/20071/9/2007APASS
DetailsForrest France
Items on previous c/n are finished, fire sprinkler permit finaled.
INSP-Sprinkler Rough-in/Hydro1/8/20071/8/20071/8/2007PPART
DetailsForrest France
Overhead hydro test passed, noted items missing for final including main drain, riser signage, head box, reliable heat for the riser room, etc.
INSP-Final Inspection1/8/20071/8/20071/8/2007PCANC
DetailsForrest France
Duplicate inspection request.
INSP-Supply line flush12/11/200612/12/200612/12/2006APART
DetailsForrest France
Fire service supply line flush completed.
INSP-Supply line flush12/4/200612/4/200612/4/2006PPART
DetailsForrest France
UG hydrostatic test of the fire supply line passed.
INSP-Sprinkler Rough-in/Hydro5/1/20065/1/20065/2/2006PPART
DetailsForrest France
Third floor is approved for cover, insulation at one area repaired while on site, missing nailer plate has been installed.
INSP-Sprinkler Rough-in/Hydro5/1/20065/3/20065/1/2006PCANC
DetailsForrest France
Scheduled by a contractor via Hello! on 5/1/2006 at 8:32:15 AM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on May 1 2006 8:36AM.
INSP-Sprinkler Rough-in/Hydro3/14/20063/15/20063/15/2006APART
DetailsForrest France
Overhead rough-in is good for cover at the 1st and 2nd floors only, 3rd floor inspected but not approved for cover until cold cavity protection has been installed and verified, missing nailer plate at third floor low wall main.