Permit NumberFIR06-00695
StatusFinaled
Name DEBEST FIRE PROTECTION
Site Address 9050 W OVERLAND RD Unit: 210
Project NameANDERSON BLACK EAGLE
Customer Number 
ePlanReview 
Description
BANNER BANK - ANDERSON BLACK EAGLE BLDG - STE 210) This building is fire sprinklered for building area increase. To create a 2,460 square foot office tenant space on the 2nd story of an existing 2 story building. The restrooms, the stairways, the elevator, the roof top mechanical units, and the corridor were all constructed under shell permit BLD05-03105. Work is to include interior nonbearing walls, wall furring and insulation, suspended ceilings, interior doors, millwork, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. The scope of the sprinkler work includes adding 22 down heads into the new wall and ceiling layout. The existing SSU heads will be removed and the outlets plugged off. When tenant work affects fire sprinkler protection outside the permitted work area due to the installation of tenant-demising or new partition walls, the affected area sprinkler coverage outside the BLD permit will fall under the Fire Permit scope of work, to maintain the required fire protection within the fire sprinklered facility. The "Riser" and its supplies which include all appurtenances (including tamper, alarm and alarm monitoring) relating to the normal and correct function and integrity of this system will fall under the jurisdiction for code compliant verification. This work is attached to BLD06-02128.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection11/6/200611/7/200611/7/2006APASS
DetailsForrest France
Fire sprinkler passed inspection, permit finaled.
INSP-Final Inspection11/3/200611/6/200611/6/2006ADEFR
DetailsForrest France
Pending alarm permit final.
INSP-Final Inspection11/3/200611/3/200611/3/2006PCANC
DetailsForrest France
Contact: Todd K; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley
INSP-Final Inspection11/1/200611/2/200611/2/2006ANR
DetailsForrest France
Final pending shell permit completion.
INSP-Sprinkler Rough-in10/30/200610/31/200610/31/2006APART
DetailsForrest France
OH rough-in inspection is okay per T. Cobbley.