Information based on query as of Sunday, June 30, 2024.
Permit Information
Permit NumberFIR06-00810
StatusFinaled
Name PEAK ALARM
Site Address 939 W BOEING ST
Project NameOROWEAT BAKERIES
Customer Number 
ePlanReview 
Description
This fire alarm permit is to install a new fire sprinkler and HVAC duct smoke detector monitoring. Building Permit BLD06-01044 is to remodel an existing 46,147 sq.ft. warehouse/office building for new tenant with bakery which includes cooking, freezing and packaging of food products per approved plans. The entire first floor and a portion of the 2nd floor to be occupied totaling 39,731 sq.ft. The balance of 6,417 sq.ft. of 2nd floor to be sealed off and not used. No information provided for the detached building on east side of property and this permit does not address occupancy of that structure. Work to include, removal of interior nonbearing partitions, cut new overhead door into existing concrete wall per approved engineering, installation of new plumbing, installation of new kitchen equipment, related site work, miscellaneous related finishes. This building is Fully Fire sprinklered for unlimited area building any alterations or modifications to the sprinkler system shall be per NFPA #13 as regulated by the fire department. RMH39
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection1/26/20071/26/20071/30/2007PPASS
DetailsTroy Cobbley
This permit is finaled. One of the two duct smoke detectors has been deleted. Thet hvac unit has been removed from the roof top as requested..
INSP-Final Inspection1/10/20071/10/20071/10/2007PFAIL
DetailsTroy Cobbley
One of the two duct detectors has been deleted. Per Mike Timmerman and I this detector needs to be installed as per the plans or the hvac unit needs to be removed. The one duct smoke detector that was installed has the sample tube installed backwards and pointing the wrong way. Also the donuts behind the detector are missing as well as the foam filters. I tested it anyway and it did shut the hvac unti down.
INSP-Final Inspection12/20/200612/27/200612/27/2006AFAIL
DetailsForrest France
The two duct detectors are not installed correctly with respect to sample tube orientation and weatherproof enclosures. The panel, batteries, phone lines, SD, manual pull, and sprinkler monitoring all tested satisfactory.
INSP-Final Inspection11/2/200611/3/200611/3/2006ANR
DetailsForrest France
Per phone call from the contractor, the project is not ready for inspection due to HVAC equipment difficulties.
INSP-Final Inspection11/2/200611/2/200611/2/2006PCANC
DetailsForrest France
No time available to complete this inspection request today, to be rescheduled per conversation with contractor.