Permit Information
Permit NumberFIR10-00300
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 10265 W ASPEN MEADOW ST
Project NameCowles Residential
Customer Number 
ePlanReview 
Description
The Fire Sprinkler Scope of work consists of a 13D sprinkler system for a residential home. The home is supplied by a dedicated 1ΒΌ" underground supply. The piping is Blaze Master CPVC.

FIRE SPRINKLERES ARE REQUIRED. Permit for the construction of a new 4,236 sq. ft. one story single family dwelling with a basement (basement 1,595 sq. ft., first story 2,641 sq. ft.) with five bedrooms, 3 1/2 bathrooms, approximately 488 sq. ft. of covered patio and a 973 sq. ft. attached garage. All work to be done per the approved plans, plan review report and any notations. R-1C zoning and setbacks per planning. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection2/8/20112/9/20112/9/2011APASS
DetailsTroy Cobbley
Permit finaled.
INSP-Final Inspection2/4/20112/4/20112/4/2011PFAIL
DetailsForrest France
Noted items include; non-functional outside bell, missing escutcheons, secure control valves, signage/calc. info at riser, provide data sheets for exposed supply pipe, pendent head at one room appears obstructed per NFPA 13D 8.2.5.2.1.
INSP-Conference12/9/201012/10/201012/10/2010ADONE
DetailsTroy Cobbley
I met with Mark from Shilo and we discussed the underground supply line being buried with out any inspections. I left a correction notice referencing IFC 106.2 and 106.3
INSP-Sprinkler Rough-in7/19/20107/19/20107/19/2010PPASS
DetailsTroy Cobbley
The sprinkler piping in the master bedroom can be covered. I discussed with Richard the requirement for me to verify underground supply piping bury depth and flushing prior to cover.
INSP-Sprinkler Rough-in7/16/20107/16/20107/16/2010PPART
DetailsTroy Cobbley
The fire sprinkler piping is ok to cover except in the southwest/master bedroom, there are tenting issues here. I went over possible sprinkler pendant obstruction issues with the builder.
INSP-Sprinkler Rough-in7/12/20107/16/20107/16/2010AFAIL
DetailsTroy Cobbley
No responce from the phone contact 30 min. prior to arriving on site. Once on site I met the builder but no city approved plans were on site for the inspection. The builder was already starting to cover the un-inspected fire sprinkler piping so I stopped that and request that the installed sheet rock be removed. I also pointed out tenting and insulation that was not installed correctly.
INSP-Sprinkler Rough-in7/12/20107/13/20107/12/2010PCANC
DetailsTroy Cobbley
later afternoon would be best if possible. Richard is the contact. Thanks Phone #: ###-#### >> Inspection requested via web by Stan Beus Inspection cancelled from web by: Stan Beus