Permit Number | FIR14-00177 |
Status | Finaled |
Name |
PHOENIX FIRE PROTECTION
|
Site Address |
7132 W TARGEE ST
|
Project Name | Gillingham Bldg 2 |
Customer Number | UDG ONLY |
ePlanReview | Yes |
Description |
The fire sprinkler scope of work consists of approximately 8” & 6” x 1330’ C-900 piping with associated fittings and thrust blocks.
(R&R TRUCK SERVICE) (GILLINGHAM BUILDING#2) Permit to construct a new 12,096 square foot non separated use, VB building and associated site work. The office portion of the structure is 1,104 square feet and service/repair area is 10,992 square feet. This building service repair area consists of 4 separate areas. The areas are separated by combustible, bearing and nonbearing walls. The office area consists of 2 offices, reception area, 2 ADA compliant restrooms and a break room. This building is fully fire sprinklered. Concrete work is to include concrete footings, concrete foundations, and concrete slabs on grade. According to the Geotechnical Investigation, this site has undocumented fill that may extend up to 45 feet below the footings of the new building. The existing material below where the spread footings will be located is required to be removed to a depth of at least 2 feet below the bottom of the proposed spread footings and replaced with structural fill. This work and all other site work is required to comply with the approved Geotechnical Investigation report and letter prepared by the Geotechnical Engineer. Special Inspections include concrete and soils. Inspections by the Geotechnical Engineer are also required.**ajs
|