Information based on query as of Wednesday, June 26, 2024.
Permit Information
Permit NumberFIR16-00427
StatusFinaled
Name PHOENIX FIRE PROTECTION
Site Address 10250 W ALPINE MEADOW ST
Project NameSlack Residence
Customer Number 
ePlanReviewYes
Description
[Slack residence]
The fire sprinkler scope of work consists of one level single family dwelling. All piping to be concealed in attic space with a minimum of R38 insulation over the piping. CPVC piping and extended coverage sprinklers are being utilized.

[BLD16-00470] - **5/11/16 Plan modification to remove basement and add 126 sq. ft. storage room in garage and remove one overhead door in detached shop.//leg** Permit for the construction of a new 3764 sq. ft., one story single family dwelling with finished basement (first story 2680 sq. ft., basement 1084 sq. ft.) with a 1200 sq. ft. detached shop. The dwelling has 5 bedrooms, 4.5 bathrooms, approximately 733 sq. ft. of covered patio/porch, 872 sq. ft. and an attached garage per the approved plans, ACCA report, as approved by planning under CZC16-00048, and any notations. R-1C zoning and setbacks per planning. //leg
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/3/201610/4/201610/4/2016PPASS
DetailsTroy Cobbley
Permit finaled
INSP-Final Inspection9/29/20169/29/20169/29/2016PFAIL
DetailsTroy Cobbley
The 2" poly piping needs to be attached to the bottom of the trusses, need the city approved plans to verify the riser layout and sizing, need the flow switch/bell repaired. I spoke to the owner(husband) about the need for more fill dirt over the underground per the agreement with the fire sprinkler contractor and builder.
INSP-Final Inspection9/23/20169/27/20169/27/2016PFAIL
DetailsJim Page
City approved drawings were not on site at time of inspection. Flow switch fire bell was not installed at time of inspection, fire plan review notes specify that the bell needs to be mounted on an exterior wall, close to the street address side of house. Numorous concealed type escutcheons are painted, all escutcheons that were painted after installation need to be replaced. Point of contact on project did not know where the underground supply came into the building, previously noted item for proper coverage above underground supply could not be verified, this will need to be addressed/verified before next inspection.
INSP-Conference9/22/20169/22/20169/23/2016PPASS
DetailsTroy Cobbley
Underground flush witnessed and passed by Tim Frost. See attached email on discussion of adequate coverage of underground supply piping.
INSP-Supply line flush9/20/20169/21/20169/21/2016PCANC
DetailsJim Page
I called and left a message with point of contact Scott Phone #: ###-#### , appears that a SUEZ representative is not scheduled to perform flush (I spoke to SUEZ and it was not on their schedule), main line underground flush will not be completed until a SUEZ representative is schedule to operate underground valve to perform mainline flush. This inspection request is cancelled and a new underground flush request will need to be rescheduled with a SUEZ rep to operate valve.
INSP-Sprinkler Rough-in/Hydro7/21/20167/22/20167/22/2016APASS
DetailsTroy Cobbley
Rough-in and tenting passed. Leroy was going to modify tenting at the west end of the house. Piping can be covered. Underground is still not deep enough and the supply piping under the house still needs verified.
INSP-Sprinkler Rough-in/Hydro7/21/20167/21/20167/21/2016PCANC
DetailsTroy Cobbley
Overbooked. Reschedule for tomorrow morning at 7:30
INSP-Sprinkler Rough-in7/20/20167/21/20167/21/2016AFAIL
DetailsTroy Cobbley
Provide the small documents, heads are located too close to one another, riser is too far from wall, tenting not complete, underground supply is too shallow..ect.
INSP-Sprinkler Rough-in/Hydro7/20/20167/21/20167/21/2016AFAIL
DetailsTroy Cobbley
This inspection was for an underground cover. Piping is installed at the other end of the house and is not at the required 4'-6" minimum bury depth. Piping can not be covererd.