Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberFIR18-00582
StatusFinaled
Name JOHNSON CONTROLS FIRE PROTECTION
Site Address 950 W STATE ST
Project NameFirst Presbyterian Church Remo
Customer Number 
ePlanReviewYes
Description
[Fire Presbyterian Church - Lobby and Restroom Remodel] - Quick Permit
Modify Fire Sprinkler system

[BLD18-01688]
Fire sprinklers used for building area increase. Permit is to remodel the existing lobby and restroom areas within the existing church building main level. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, removal of select suspended acoustic ceiling, removal of select plumbing fixtures, removal of select millwork, construction of interior non-bearing walls to create accessible restrooms and new accessible restroom accessories, select new door/door frames, select new plumbing fixtures, select new gypsum ceiling, select new light fixtures, select new millwork, a new interior lobby metal roof awning, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection8/28/20188/29/20188/29/2018APASS
DetailsTroy Cobbley
Permit finaled

Contact Gordon and associated number for time. Phone #: ###-#### Inspection requested via web by Shane Lesteberg
INSP-Conference8/7/20188/7/20188/7/2018ADONE
DetailsJim Page
During the rough-in inspection for newly installed overhead fire sprinkler piping it was noticed that the premise still has o-ring style heads throughout the building that need to be replaced (O-ring style heads must be replaced due to o-ring style sprinkler heads failing to operate correctly). O-ring style heads must be replaced before fire sprinkler final inspection and fire life safety inspection. After discussion with Ron Johnson with Boise Fire, final inspections will be failed on fire sprinkler and life safety if o-ring style heads are not replaced.
INSP-Sprinkler Rough-in8/6/20188/7/20188/7/2018APASS
DetailsJim Page
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, approved for cover.

Todd Phone #: ###-####