Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberGCB11-00037
StatusFinaled
Name Judith Adams
Site Address 8726 W RINGBILL CT
Project NameBLD2011-00036
Customer Number 
ePlanReviewNo
Description
Single Family Dwelling Alteration per Abatement Inspection report - To restore an existing Single Family Dwelling attached garage back to original configuration per the approved plans. Work to include: Provide dwelling/garage separation with 1/2-inch gypsum board sheetrock applied to the garage side; provide dwelling/garage opening protection w/ a min. 1-3/8-inch solid or honeycomb core steel door; provide mechanical ventilation in the bathroom; provide smoke alarms and carbon monoxide alarms; provide corrections to electrical and plumbing installation; and all other work per the approved plans, correction notice, and the Inspectors final approvals. A certificate of completetion shall be issued when work is completed and a final inspection has occurred. **SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final6/2/20116/14/20116/13/2011ADONE
DetailsBob Archibald
check on finals for c/o
GCB-Final6/1/20116/2/20116/2/2011APASS
DetailsDave Hannah
Final (associated with Code Enforcement Case CED2###-####0)Judith @ ###-####Call in advance talked with bob arcibald about this project ok to final