GCB-Final | 3/28/2012 | 3/29/2012 | 3/29/2012 | A | PASS |
Mike Jordan
|
|
|
Jerry @ ###-####. All issues resolved. Structural final only ok.
|
GCB-Final | 3/27/2012 | 3/28/2012 | 3/28/2012 | P | FAIL |
Mike Jordan
|
|
|
Jerry @ ###-#### PM Inspection. Remove thumb turn from main entry door, provide sticker over main door "Yhis door to remain unlocked during bussiness hours" provide fire extinguishers, provide ada bathroom sign and post at required location.
|
GCB-Ceiling Grid | 3/15/2012 | 3/16/2012 | 3/16/2012 | A | DONE |
Dave Hannah
|
|
|
Jerry @ ###-####
|
GCB-Energy | 3/12/2012 | 3/13/2012 | 3/13/2012 | A | PASS |
Mike Jordan
|
|
|
Jerry @ ###-####. OK to sheet rock.
|
GCB-Framing | 3/12/2012 | 3/12/2012 | 3/12/2012 | P | PASS |
Mike Jordan
|
|
|
Jerry Phone #: ###-####. Airseal and fireblock completed. Ok to insulate.
|
GCB-Framing | 3/8/2012 | 3/9/2012 | 3/9/2012 | A | PART |
Mike Jordan
|
|
|
Jerry @ ###-####. Framing ok. Needs to complte sirseal and fire stop penetrations through top plates and at ceiling level along existing building.
|
GCB-Masonry | 2/21/2012 | 2/22/2012 | 2/22/2012 | A | PART |
Dave Hannah
|
|
|
Jerry @ ###-####Rebar crew is toping out last lift
|
GCB-Masonry | 2/17/2012 | 2/17/2012 | 2/17/2012 | P | PASS |
Tom Arcoraci
|
|
|
|
GCB-Masonry | 2/16/2012 | 2/17/2012 | 2/17/2012 | A | CANC |
Tom Arcoraci
|
|
|
Jerry @ ###-####(Rebar Inspection)
|
GCB-Shearwall | 2/14/2012 | 2/15/2012 | 2/15/2012 | A | PASS |
Mike Jordan
|
|
|
Jerry @ ###-####. Exterior shear nail ok. Reviewed and inspected truss repair from truss enginneer for roof trusses that have benn installed upside down. Inspected the 32/16 span rated osb on both sides with required nailing. ok to cover exterior sheathing only.
|
GCB-Framing | 2/3/2012 | 2/6/2012 | 2/6/2012 | A | FAIL |
Mike Jordan
|
|
|
Jerry @ ###-####. Nails are over driven. Needs to renail. Also need RFI from engineer for repair on roof trusses that have been installed upside down.
|
GCB-Fndatn/slab ins/fld vent | 1/20/2012 | 1/23/2012 | 1/23/2012 | A | PASS |
Dave Hannah
|
|
|
Jerry @ ###-####
|
GCB-Footing | 1/19/2012 | 1/20/2012 | 1/20/2012 | A | PASS |
Dave Hannah
|
|
|
Jerry @ ###-####3 PM Inspection
|
GCB-Footing | 12/14/2011 | 12/15/2011 | 12/15/2011 | A | PASS |
Mike Jordan
|
|
|
Jerry @ ###-####11 a.m. inspection. Footing ok. Needs to have architect and engineer re-evaluate existing footing and foundation system.
|