Description |
***9/3/2014 PLAN MODIFICATION TO INCLUDE: ALLOW THE PLYWOOD SHEATHING TO REMAIN DUE TO THE PLYWOOD BEING NON-STRUCTURAL; AND ALLOW T1-11 PLYWOOD TO REPLACE THE METAL SIDING ON THE SOUTH BUILDING FACE. ALL WORK PER THE ARCHITECTS EVALUATION REPORT AND THE STRUCTURAL INSPECTORS FINAL APPROVAL. SRZ*** To repair an existing 578 square foot existing detached accessory building located on the northwest portion of this property that was damaged by a fire. Work to include: remove scrape all charring from the structural members, trusses, and posts (if charring depth exceeds 1/2" on each face, the member requires replacement); replace all wood straps/ties; replace all horizontal framing where charring occurred; replace all plywood sheathing where charring has destroyed the facing; replace the charred door framing (east side of door); and replace the metal siding on the south building face. All work per the approved plans, attached plan review report, and the structural inspector’s final approval. **SRZ**
|