Permit Information
Permit NumberMEC05-02023
StatusFinaled
Name ADVANCED HEATING & COOLING
Site Address 650 N STRATA VIA WAY
Project Name 
Customer Number 
ePlanReview 
Description
Mechanical Permit - New: 1 - 120,000 BTU Gas Furnace/5-Ton A/C & Coil; Gas Piping to: Furnace, water heater, range, bbq & fireplace; Venting in: Bathrooms, kitchen & laundry; 42" Gas Fireplace; 2-Zone System; Programmable Thermostat
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/12/20061/13/20061/13/2006APASS
DetailsTroy James
Per Dixie - need to reschedule for AM Friday 1/13.; Phone #: ###-#### x202 Internet Inspection Request from: Patti Forsythe
Final1/10/20061/11/20061/11/2006PPEND
DetailsDixie Fellows
Please call Patti re: access; Phone #: ###-#### x202 Internet Inspection Request from: Patti Forsythe...out of time..i called patti to reschedule
Rough-in8/23/20058/23/20058/23/2005APASS
DetailsDixie Fellows
Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson
Rough-in8/22/20058/22/20058/22/2005PFAIL
DetailsTroy James
Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson
talked to contractor to provide combustion air and clearance to b-vent and framer to build platform to inline exhaust fan in attic and to revise permit to show the correct amount of fans and fireplaces installed
Pressure Test8/19/20058/23/20058/22/2005ACANC
DetailsDixie Fellows
Re-Inspect; Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson Inspection cancelled from web by: Jennifer Jenson
Rough-in8/19/20058/23/20058/22/2005ACANC
DetailsDixie Fellows
Re-inspect; Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson Inspection cancelled from web by: Jennifer Jenson
Rough-in8/18/20058/19/20058/19/2005AFAIL
DetailsBill VanDegrift
Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson provide 1" clearance on both fire place flues. provide clearance and hang water heater B-vent. seal kitchen exhaust duct. update fixture count on permit. seal return air duct by furnace. use metal duct for makeup air to mech room. called their office with the last correction because I forgot to include it on the correction notice.
Pressure Test8/18/20058/19/20058/19/2005APASS
DetailsBill VanDegrift
Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson gas test ok
Pressure Test7/26/20057/27/20057/27/2005ANR
DetailsDixie Fellows
Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson
Rough-in7/26/20057/27/20057/27/2005ANR
DetailsDixie Fellows
Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson..call for conference