Final | 3/9/2017 | 3/9/2017 | 3/9/2017 | P | PASS |
Brian Scoles
|
|
|
please call half hour prior Phone #: ###-#### Inspection requested via web by thomas nguyen-
|
Mec-Aging Inspection | 2/20/2017 | 2/20/2017 | 2/21/2017 | | PEND |
Ben Livingston
|
|
|
|
Conference | 11/20/2016 | 11/21/2016 | 11/21/2016 | A | FAIL |
Ben Livingston
|
|
|
please call ahead of time Phone #: ###-#### Inspection requested via web by thomas nguyen
duct on crawl needs to be supported to structure, length need to be limited. need air balance report, and duct blast need approved condensate fitting on furnace return plenum cannot have romex in it. 6" fresh air needs to be insulated bedroom need transer over the door, flue needs to be refirecaulked
|
Pressure Test | 7/21/2016 | 7/21/2016 | 7/21/2016 | A | PASS |
Ben Livingston
|
|
|
5lb flue
|
Conference | 7/14/2016 | 7/15/2016 | 7/15/2016 | A | CANC |
Ben Livingston
|
|
|
please call Marco half hour priority Phone #: ###-#### Inspection requested via web by thomas nguyen
|
Rough-in | 7/15/2016 | 7/15/2016 | 7/15/2016 | A | PART |
Ben Livingston
|
|
|
20 lb gas, rough in,,,,, flue needs to be retested
|
Rough-in | 7/14/2016 | 7/14/2016 | 7/14/2016 | A | FAIL |
Ben Livingston
|
|
|
please call half hour priorty Phone #: ###-#### Inspection requested via web by thomas nguyen- need to make manual j approved for roughin
|