Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberMEC18-00246
StatusFinaled
Name TML LLC
Site Address 1323 N FRAZIER AVE
Project Name 
Customer Number22319-23
ePlanReviewNo
Description
Complete HVAC Installation: Install new HVAC system // fireplace included in installation TCH 1/24/18
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/10/20184/10/20184/10/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- fireplace and final ok
Final4/9/20184/9/20184/9/2018PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- need to firecaulk outside air at ceiling in garage and insulate- flexible b vent \needs 1" clearance to PVC flue- pvc flue needs fire caulked- dryer vent vent needs sealed in laundry room at floor in box- b vent needs fire caulked at ceiling in garage- left correction notice on filter clip in garage
Pressure Test2/5/20182/6/20182/6/2018ACANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- already witnessed this test
Rough-in2/5/20182/6/20182/6/2018APASS
DetailsBrian Scoles
FP inspection also please Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok- fireplace R/I ok
Rough-in2/5/20182/6/20182/5/2018ACANC
DetailsBrian Scoles
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
Rough-in1/30/20181/30/20181/30/2018PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- fresh air needs to be ran in 6" round pipe per manual J and insulated in attic and garage- missing 14x4 transfer opening master bedroom first floor- need all framing completed in closet 2nd floor, laundry room and garage- left correction notice front window
Pressure Test1/30/20181/30/20181/30/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
Conference1/29/20181/30/20181/30/2018PPASS
DetailsBrian Scoles
witness d blast 115 pm Phone #: ###-#### Inspection requested via web by dannyel chaloupka- duct blast test pass
Rough-in1/29/20181/30/20181/30/2018ACANC
DetailsBrian Scoles
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
Pressure Test1/29/20181/30/20181/30/2018ACANC
DetailsBrian Scoles
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
Rough-in1/26/20181/29/20181/29/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- need approved manual J onsite
Pressure Test1/26/20181/29/20181/29/2018AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gas below 20 psi