Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberMEC18-02125
StatusFinaled
Name ICON AIR
Site Address 2704 N COOLWATER AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: HVAC Installation
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/18/20187/19/20187/19/2018APASS
DetailsBrian Scoles
Final Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
Final7/16/20187/17/20187/17/2018PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- need uv protection on lineset at condenser
Conference6/15/20186/18/20186/18/2018APASS
DetailsBrian Scoles
Blast witness at 9:30 please.
Questions please call Randy ###-#### Phone #: ###-#### Inspection requested via web by Randy Hart- duct blast test pass
Conference6/14/20186/15/20186/15/2018ACANC
DetailsBrian Scoles
Blast witness at 9:30 Please.
Questions please call Randy ###-#### Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
Conference6/6/20186/7/20186/6/2018ACANC
DetailsBrian Scoles
Blast Witness at 10 am
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
Conference6/6/20186/6/20186/6/2018ACANC
DetailsBrian Scoles
10AM Blast witness please.
Questions please call Randy ###-#### Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
Conference5/29/20185/29/20185/29/2018AFAIL
DetailsBrian Scoles
Blast witness at 9:30 Please Phone #: ###-#### Inspection requested via web by Randy Hart- needs work
Rough-in5/18/20185/21/20185/21/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
Rough-in5/16/20185/17/20185/17/2018PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- b vent in garage needs 1" clearance to combustibles need to remove part of 2x4 nailer at ceiling- exhaust fans (all) need sealed/taped at fan to galv- b vent in needs firestop installed and insulation shield needs to go to roof and firecaulk at floor missing- need to firecaulk R/A duct at ceiling and floor in chase- left correction notice front window
Rough-in5/16/20185/16/20185/16/2018PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- need approved ACCA report onsite for inspection
Pressure Test5/16/20185/16/20185/16/2018PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass