Permit Information
Permit NumberMEC18-02222
StatusFinaled
Name CARLON INC
Site Address 2003 N BEACH ST
Project NameGurbacki kitchen
Customer Number18-026
ePlanReviewNo
Description
Alteration or Repair: Install new furnace using existing a/c units,replacing ducts to R-8, new water heater, gas piping, venting
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/4/20189/5/20189/5/2018APASS
DetailsJack Reynolds
Jonny Phone #: ###-####
Final8/28/20188/29/20188/29/2018AFAIL
DetailsJack Reynolds
if no body there call for access // Jonny Phone #: ###-####
- furnace in basement needs a wet switchh installed in the secoundary- condensate drain for heating side of furnace is not ran- need to finish duct seal- upstairs furnace needs lineset insulation fixed- need drip leg in gas line- need to finish duct seal- kitcken exhaust ok
Pressure Test8/1/20188/1/20188/1/2018PPASS
DetailsChad Schwendiman
5lb flue
Final7/30/20187/31/20187/31/2018ACANC
DetailsJack Reynolds
(gas/range)- Johnny Phone #: ###-####
should have been a R/I for the range- i also need to see a 5lb flue test on upstairs furnace still
Rough-in7/31/20187/31/20187/31/2018PPASS
DetailsJack Reynolds
(gas/range)- Johnny Phone #: ###-####
R/I ok on range
Rough-in6/12/20186/13/20186/13/2018APASS
DetailsChad Schwendiman
johnny Phone #: ###-#### - No range vent installed at this time
Pressure Test5/30/20185/31/20185/31/2018APART
DetailsChad Schwendiman
Johnny-- gas pressure test- are 2 furnaces, need to pay for other one Phone #: ###-#### - 5lb flue fail for upstairs furnace, 5lb flue pass for furnace in basement, 20lb gas pass