Permit Information
Permit NumberMEC18-03518
StatusFinaled
Name CHATEAU LES BOIS PROPERTY OWNERS
Site Address 1163 N CAMELOT DR
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Installation of new HVAC
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/20/20188/20/20188/20/2018APASS
DetailsBrian Scoles
furnace a/c coil co ok
Rough-in8/19/20188/20/20188/20/2018ACANC
DetailsBrian Scoles
As per the previous inspection, all the rubber flexible couplings were replaced with more appropriate PVC unions; a cleanout Tee was added right downstream to the outlet of the furnace exhaust. The vent piping was pressurized at 5 psig for more than 48h without any change in the gauge. The threaded test plug in the cleanout Tee and the pressure gauge, along with the air compressor will be available for a live test. As in previous occasions, call Tona at ###-#### or Nicole at ###-#### about 25 minutes before to drive to the condo.

Thanks! Phone #: ###-#### Inspection requested via web by Nicole Yogerst
Rough-in8/12/20188/13/20188/13/2018PFAIL
DetailsBrian Scoles
As discussed in the previous rough-in inspection, I have completed the installation of the furnace, evaporator coil and condensing unit. Please call Tona at ###-#### or myself at ###-####, 25 minutes before arriving. Phone #: ###-#### Inspection requested via web by Nicole Yogerst- need to pressure test flue- rest is good- recall in inspection when ready
Rough-in7/19/20187/19/20187/20/2018PDONE
DetailsBrian Scoles
Please meet plumbing inspector at residence at 1:30PM on 07/19/2018. Thank you! Phone #: ###-#### Inspection requested via web by Nicole Yogerst- went over furnace a/c install- will need a flue test 5 psi on 15 psi gauge max