Final | 4/16/2019 | 4/16/2019 | 4/16/2019 | P | PASS |
Jack Reynolds
|
|
|
Please call the number provided when on the way out. Phone #: ###-#### Inspection requested via web by Steve Bunch - final ok
|
Mec-Aging Inspection | 4/9/2019 | 4/9/2019 | 4/9/2019 | | DONE |
Jack Reynolds
|
|
|
WIP
|
Rough-in | 8/22/2018 | 8/23/2018 | 8/23/2018 | A | PASS |
Jack Reynolds
|
|
|
call for access code // Steve Phone #: ###-#### - drip leg ok- crawl access/light and furnace disconnect ok- b vent clearances ok- fresh air ok- duct blast ok- R/I and cover ok
|
Rough-in | 8/10/2018 | 8/14/2018 | 8/14/2018 | P | FAIL |
Jack Reynolds
|
|
|
Steve-call for access code Phone #: ###-####- need a drip leg in gas line at furnace- B vent coming through floor needs 1" clearances- furnace needs service discconect and light in crawl- access opening into crawl is too small needs to be 22x 30 - make sure that toe kicks in two locations are ducted all the way to the register- need to see 6" fresh air intake
|
Rough-in | 7/31/2018 | 7/31/2018 | 7/31/2018 | P | FAIL |
Jack Reynolds
|
|
|
- B vent for furnace needs 1" clearances in the crawl space, main floor in the closet where in goes into the wall, and i need to see an insulation sheild in the attic -Main supply trunk in the crawl is laying on the ground and has the B vent laying on it- supply branches need dampers for air balancing and supply boots sealed - need service dissconnect for the furnace in the crawl space and a light - need to know where the crawl access is going to be and how big it is going to be for removal of equipment if needed - Line set insulation needs fixed and UV tape- penetration out the foundation needs to be sealed and the breaker size is too large- power whip to A/C needs to be weather tight - range hood vent is not tied into termination properly - need to see that the permit has exhaust fans, range hood,and duct work added and fees paid - Man J. needs to be performed and approved by the city of boise
|
Rough-in | 7/30/2018 | 7/31/2018 | 7/31/2018 | P | FAIL |
Jack Reynolds
|
|
|
vacant, call for access code - Steve Phone #: ###-####- no access called steve and left message
|
Rough-in | 7/27/2018 | 7/30/2018 | 7/30/2018 | A | CANC |
Jack Reynolds
|
|
|
Shaun or Steve ###-#### Phone #: ###-####5
|
Rough-in | 7/27/2018 | 7/27/2018 | 7/27/2018 | P | NH |
Jack Reynolds
|
|
|
Call for access // Sean Phone #: ###-#### - no access to home called number no answer and voice mail was full
|