Permit Information
Permit NumberMEC19-00581
StatusFinaled
Name ADVANCED HEATING & COOLING
Site Address 2001 S HUDSON AVE
Project Name 
Customer Number 
ePlanReviewNo
Description
New: HVAC
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/11/20197/12/20197/12/2019APASS
DetailsJack Reynolds
Requesting a Final Inspection for Friday. Please contact Mark ###-#### or Daryl ###-#### before coming out Phone #: ###-#### Inspection requested via web by Heather
-Gransbery
- final ok
- signed occ card
Final7/10/20197/11/20197/11/2019AFAIL
DetailsJack Reynolds
Requesting a Final Inspection for Thursday. Please contact Mark ###-#### or Daryl ###-#### before coming out Phone #: ###-#### Inspection requested via web by Heather Gransbery
- access doors need labeled
- line sets need UV protection
- condensate lines need installed
Rough-in6/28/20197/1/20197/1/2019APART
DetailsJack Reynolds
Requesting an R/I inspection for the Mechanical Room on 7-1-19. Please call Mark before coming out - ###-#### Phone #: ###-#### Inspection requested via web by Heather Gransbery
- duct work in mech room ok
- need to see pool heater install instructions for venting
- b vent for pool heater needs 1" to combustibles and one location needs clearance reduction installed
- mech room needs damper signage installed on wall for final
- access doors need installed in ceiling for hvac zones
Rough-in4/17/20194/18/20194/18/2019APASS
DetailsJack Reynolds
vent piping rough-in
Rough-in4/16/20194/17/20194/17/2019PFAIL
DetailsJack Reynolds
Request for inspection on the flue pipe. Please contact Daryl ###-#### with any questions or concerns. Inspection requested via web by Heather Gransbery
- south side vent has screw penetrating inner pipe
Rough-in4/16/20194/16/20194/16/2019AFAIL
DetailsJack Reynolds
-B vent for both pool heaters has screws penetrating inner pipe and needs to be changed out
- both vents need an insulation sheild intalled to maintain 1" clearances
Rough-in3/21/20193/22/20193/22/2019AFAIL
DetailsJack Reynolds
Request for cover R/I inspection. Please contact job lead Daryl with any questions or concerns. ###-#### Inspection requested via web by Heather Gransbery
-
Rough-in3/1/20193/4/20193/4/2019APART
DetailsJack Reynolds
request for sealer inspection. Please contact job lead Daryl ###-#### with any questions or concerns. Inspection requested via web by Heather Gransbery
- duct seal inspection on clubhouse ok for insulation