Permit Information
Permit NumberMEC19-04326
StatusFinaled
Name ALLEY HEATING & COOLING
Site Address 1447 N PINEVIEW LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete HVAC Installation: furn,ac,bath vent,dr vent,kiitch vent,gas pipe
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final1/6/20201/7/20201/7/2020APASS
DetailsBrian Scoles
CORRECTION MADE MAN J INSIDE INFORMATION BIN BY ELECTRICAL PANEL LOCK BOX CODE 0124 Phone #: ###-#### Inspection requested via web by Oleg Chervak
Final1/3/20201/3/20201/3/2020PFAIL
DetailsBrian Scoles
GARAGE CD 1234 Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- approved man j onsite
2- condensate to washer box needs completed
3- seal exterior gas line penetration at meter
Rough-in10/2/201910/3/201910/3/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
Final10/2/201910/3/201910/3/2019PCANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak
Rough-in10/1/201910/2/201910/2/2019PFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- not all corrections made- see notice on sliding door
Pressure Test10/1/201910/2/201910/2/2019PPASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- already completed
Rough-in10/1/201910/1/201910/1/2019PCANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- wont be ready y time i come back by- reschedule
Pressure Test10/1/201910/1/201910/1/2019PCANC
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- already completed
Rough-in9/30/201910/1/201910/1/2019AFAIL
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak-
1- need ladder provided by contractor to access furnace in attic
2- framing needs completed around b vent 2nd floor and draftstop installled
3- exhaust fan 2nd floor shall terminate 4 feet from property line
4- need to insulate bare metal in att supply and r/a
5- need to seal dryer duct to termination box
6- need 6" fresh air installed and maintain 10 feet from exhaust ducts
7- flue shall be b vent off furnace remove single wall pipe/fitting
left notice
Pressure Test9/30/201910/1/201910/1/2019APASS
DetailsBrian Scoles
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location