Final | 2/18/2020 | 2/18/2020 | 2/18/2020 | P | PASS |
Brian Scoles
|
|
|
Mechanical Gas Fireplace Final Inspection. Manual is in kitchen drawer. Garage Code: 4321 Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace final x 2 ok
|
Final | 2/17/2020 | 2/18/2020 | 2/18/2020 | A | NH |
Brian Scoles
|
|
|
Mechanical Gas Fireplace Final Inspection. Manual is in kitchen drawer. Please contact: Robert @ ###-#### before heading there. Phone #: ###-#### Inspection requested via web by Dan Otero- called number listed no answer- went by house all locked up
|
Rough-in | 1/3/2020 | 1/6/2020 | 1/6/2020 | A | PASS |
Ben Livingston
|
|
|
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero - fireplace x2 -
|
Rough-in | 12/31/2019 | 1/2/2020 | 1/2/2020 | A | FAIL |
Brian Scoles
|
|
|
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero- horizontal piping needs 3" clearance on top of pipe- need to install plywood in framing in attic around flue framing so no insulation can get in- pipe used does not have label on it pipe, one piece of pipe is painted black need to replace off fireplace in bathroom- living room fireplace ok- need to update permit to new construction for 2 fireplaces and change valuation and pay fees this is not an alteration
|