MIS-Aging Inspection | 8/19/2014 | 8/19/2014 | 8/20/2014 | | DONE |
Tony Young
|
|
|
|
DOC - Permit Finaled | 8/20/2014 | 8/20/2014 | 8/20/2014 | P | PASS |
Tony Young
|
|
|
permits issued
|
ELE-Conference | 5/6/2014 | 5/7/2014 | 5/7/2014 | A | DONE |
Rock A. Hudson
|
|
|
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with grounding/safety. Elecgtrical contractor to go through house, secure permit, install proper devices on ungrounded circuits, install tamper resistant recepticals wher changed on grounded circuits, install spark rings where needed, install peninsula receptical, GFCI kitchen counter recepticals, remove flexible cord behind fireplace up high, and check for 15 amp wire install on 20 amp breaker for kitchen lighting
|
BLD-Conference | 5/6/2014 | 5/7/2014 | 5/7/2014 | A | FAIL |
Tom Arcoraci
|
|
|
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with appears to have removed false drop ceiling did not touch struc framing needs permit for laundry room framing sheet rocked over lath and plaster ceilings ok. un permitted additions done years ago
|
MEC-Conference | 5/6/2014 | 5/7/2014 | 5/6/2014 | P | FAIL |
Bill VanDegrift
|
|
|
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with grounding/safety. 1) tune up dryer vent 2) complete gas piping upgrades and test 3) install b-vent from furnace and water heater for clearances 4) check combustion air for furnace and water heater 5) permit all mechanical work
|
PLM-Conference | 5/6/2014 | 5/7/2014 | 5/6/2014 | A | FAIL |
Bill VanDegrift
|
|
|
complaint doing work without permit; remodel inside including elec, plm, mech. Changed utility room into bathroom and moved utility room to basement, kitchen remodel changed flat ceiling to vaulted ceiliing. Electrical concerns with grounding/safety. 1) trap and vent washer box 2) vent lav behind the washer box 3)weep hole required on water heater t&p 4)install directional fitting in 3" waste line in basement ceiling by bath 5) permit allplumbing work
|