Permit Information
Permit NumberPLM02-03206
StatusFinaled
Name INTEGRITY PLUMBING
Site Address 12570 W FAIRVIEW AVE
Project NameTOWN & COUNTY-BLDG #1
Customer Number 
ePlanReview 
Description
kitchen to include prep sink, 3 comp sinks, hand sink , bathroom $8,000.00 initial cert aml
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/27/20036/27/20036/27/2003PPASS
DetailsJim Johnson
rob; Phone #: ###-#### Internet Inspection Request from: Annette Moore
Final6/26/20036/26/20036/26/2003PPART
DetailsJim Johnson
Scheduled by a contractor via Hello! on 6/26/2003 at 7:34:35 AM. Contact: ###-####. need R.P. for smoke house unit,s caulk all fixtures to wall provide air gap on case drain,s to hub & floor sinks remove test plug from grease interceptor vent need to provide protective cover for p-trap and hot water side under handicapp lav in rest room also bolt down gas tight lides to grease interceptor contractor to recall when ready 6/26/2003 5:00:58 PM
PLM-Aging Inspection4/28/20034/28/20034/28/2003 PASS
DetailsJim Johnson
still working on project 4/28/2003 8:30:05 AM
Plumbing Rough-in2/25/20032/25/20032/25/2003PPASS
DetailsJim Johnson
Scheduled by a contractor via Hello! on 2/25/2003 at 7:39:37 AM. Contact: ###-####.
Plumbing Rough-in2/20/20032/20/20032/20/2003PFAIL
DetailsJim Johnson
Scheduled by a contractor via Hello! on 2/20/2003 at 8:43:20 AM. Contact: ###-####. air test on sanitary sewer failed need to find vent for trench drain and tie in to vent system 2/21/2003 8:36:24 AM
PLM-Aging Inspection1/22/20031/22/20031/22/2003 PASS
DetailsJim Johnson
called contractor project still under construction getting ready to start rough-in 1/22/2003 11:32:28 AM
Groundwork11/12/200211/12/200211/12/2002PPASS
DetailsJim Johnson
Plumbing Rough-in11/12/200211/12/200211/12/2002APART
DetailsJim Johnson
Scheduled by a contractor via Hello! on 11/12/2002 at 06:23:00. Contact: ###-####.need to test grease intercepter and plumber missed floor sink in groundwork need to install trap and vent and retest ground work ok to cover portion of ground work that was tested contractor to recall when ready 11/12/2002 12:02:32 PM
Plumbing Rough-in11/7/200211/7/200211/7/2002PPART
DetailsJim Johnson
###-#### back side of grease interceptor and sanitary sewer system in side bulding test ok ok to cover grease system piping and grease interceptor still need to be tested 11/7/2002 4:42:24 PM