Permit Information
Permit NumberPLM15-04345
StatusFinaled
Name LACY MECHANICAL INC
Site Address 2581 S BROADWAY AVE
Project NameJacksons Broadway
Customer Number15128-1-1-
ePlanReviewNo
Description
Alteration: Plumbing drains vents and water piping including fixtures for new Jackson''s store. Also, including car wash piping and sumps.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/13/20164/13/20164/13/2016PPASS
DetailsEric Strole
Final4/12/20164/13/20164/13/2016APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Brent Lacy-Need seperate waterline for soap dispensor at mop sink.Temp final ok
Final4/8/20164/8/20164/8/2016PFAIL
DetailsEric Strole
Please make this around 4:00 if possible to insure that the Backflow tester has made it there. Phone #: ###-#### Inspection requested via web by Brent Lacy-The vent for the vapor compartment on the fuel interceptor shall be independently vented.(cannot tie into ant other vent) T&P for water heater requires an air-gap.
Water and/or Sewer4/8/20164/8/20164/8/2016PCANC
DetailsEric Strole
Please make this around 4:00 if possible to insure that the Backflow tester has made it there. Phone #: ###-#### >> Inspection requested via web by Brent Lacy Inspection cancelled from web by: Brent Lacy
Water and/or Sewer2/29/20162/29/20162/29/2016PPART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Brent Lacy-Water and sewer pass.
Water and/or Sewer2/26/20162/29/20162/29/2016AFAIL
DetailsEric Strole
Please schedule for late morning. Around 10:30-11 am. Thank you! Phone #: ###-#### Inspection requested via web by Brent Lacy-Corrections not complete
Water and/or Sewer2/25/20162/26/20162/26/2016PFAIL
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Brent Lacy-Sewer not complete, need test on sewer. Need clean fill under and around water and sewer. Test on water pass.
Plumbing Rough-in2/9/20162/10/20162/10/2016APART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Brent Lacy-Store area rough-in pass.
Other1/19/20161/19/20161/19/2016PPART
DetailsEric Strole
Grease interceptor has been piped with 6" through tank. Need reinspection. Phone #: ###-#### Inspection requested via web by Brent Lacy-Test on interceptor pass. Still need sewer tie-in.
Other1/15/20161/19/20161/19/2016ACANC
DetailsEric Strole
Need inspection for flammable liquids interceptor and car wash tank. Phone #: ###-#### >> Inspection requested via web by Brent Lacy Inspection cancelled from web by: Brent Lacy
Other1/15/20161/15/20161/15/2016PFAIL
DetailsBill VanDegrift
need to pipe through the tank with 6" per plans
Groundwork12/23/201512/23/201512/23/2015PPART
DetailsEric Strole
Phone #: ###-#### Inspection requested via web by Brent Lacy-G/W inside building pass. Still need carwash.
Water and/or Sewer12/22/201512/22/201512/22/2015PPART
DetailsEric Strole
Waterline into building and 10' out side of building test ok. Need tracer wire.
Groundwork12/21/201512/22/201512/22/2015APART
DetailsEric Strole
Inspection needed first thing in the morning. Inspection requested via web by Brent Lacy-Section complete is marked on plans