Information based on query as of Tuesday, June 25, 2024.
Permit Information
Permit NumberPLM16-02557
StatusFinaled
Name MERIDIAN PLUMBING CO INC
Site Address 1197 N FRAZIER PL
Project Name 
Customer Number168014
ePlanReviewNo
Description
Complete Plumbing Installation: RESIDENTIAL NEW CONSTRUCTION PLUMBING FOR 2 STORY HABITAT HOUSE
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/16/20168/17/20168/17/2016APASS
DetailsJim Little
HABITAT NEW CONSTRUCTION PLUMBING FINAL TRIM Phone #: ###-#### Inspection requested via web by Chris Field
Plumbing Rough-in7/22/20167/22/20167/22/2016PPASS
DetailsJim Little
PLEASE COME LATER IN AFTERNOON. Phone #: ###-#### Inspection requested via web by Chris Field
Plumbing Rough-in7/21/20167/22/20167/22/2016AFAIL
DetailsJim Little
JOB SUPER: PAUL Phone #: ###-#### Inspection requested via web by Chris Field
>dwv test fail
Water and/or Sewer7/21/20167/22/20167/21/2016ACANC
DetailsJim Little
SITE SUPER:PAUL, ###-#### ROUGH IN REINSPECT Phone #: ###-#### >> Inspection requested via web by Chris Field Inspection cancelled from web by: Chris Field
Plumbing Rough-in7/20/20167/21/20167/21/2016ACANC
DetailsJim Little
ROUGH IN REINSPECT AFTER CORRECTIONS. Phone #: ###-#### >> Inspection requested via web by Chris Field Inspection cancelled from web by: Chris Field
Plumbing Rough-in7/15/20167/18/20167/18/2016PFAIL
DetailsJim Little
SITE SUPER: PAUL, ###-####. PLUMBING ROUGH IN Phone #: ###-#### Inspection requested via web by Chris Field
>need to roll vent above centerline on tub and wc in o/head.
>santee @ wc on main floor needs to be on vent not flange.
>nail plate top of wall behind upstairs tub and cold to washer box on main floor.
>3" trap to big for condensate, change to 2"