Permit Information
Permit NumberPLM18-02679
StatusVoid/No Violation
Name APPLE PLUMBING AND REMODELING
Site Address 10126 W FLORENCE CT
Project Name 
Customer Number 
ePlanReviewNo
Description
Alteration or Repair: Installed new backflow
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/29/20187/2/20187/2/2018AFAIL
DetailsDan Ediger
Backflow was tested and passed by Pacific Backflow. Phone #: ###-#### Inspection requested via web by McKenna Haycock.
1. The double check valve is not an approved backflow assembly for irrigation per ISPC. Any backflow assembly that is changed out must be brought up to code.
2. PVC male fitting must be a minimum of schedule 80. ISPC 605.12.3