Permit NumberPLM96-01965
StatusFinaled
Name RANDY HOLMES
Site Address 1009 N HARRISON BLVD
Project Name 
Customer Number 
ePlanReview 
Description
PERMIT CLOSED OUT AT FAILED ROUGH-IN STAGE. NEW CONTRACTOR TAKING OVER JOB.AJB PER JIM SODEN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP - Final11/17/199811/18/199811/18/1998PPASS
DetailsJim Soden
11/18/98 347 -
INSP - Final7/23/19967/23/19967/23/1996PFAIL
DetailsJim Soden
MITCHELL PLUMBING RELEASED FROM JOB BY OWNER. FAILED PER JIM SODEN
INSP - Water lines7/19/19967/22/19967/22/1996AFAIL
DetailsJim Soden
07/19/96 347 - FAIL R/I 7/23/6 347 support both shr valves extend outside vent above roof 6"--t&p discharge line required(o/k to discharge into w/b---150# pressure test required on hot and cold polybutylene water piping---water leaks at (test) valve on north side of basement and w/b----resize water piping per code (low pressure range)
INSP - Ground work7/9/19967/9/19967/9/1996PPASS
DetailsJim Soden
07/09/96 347 - g/w o/k 7/9/6 347