Information based on query as of Sunday, May 19, 2024.
Permit Information
Permit NumberBLD18-04312
StatusFinaled
Name SUMMIT43 CONSTRUCTION LLC
Site Address 3515 W STATE ST
Project NameThe Dutch Goose
Customer Number 
ePlanReviewNo
Description
(THE DUTCH GOOSE) Permit for tenant improvements to an existing 4,088 sq ft restaurant. Work to include: demolition of existing interior, non-structural partition walls, soffit, ceiling, and kitchen; new exterior window, and façade at corner; installation of new interior non-bearing partition walls and doors; new kitchen equipment; new restrooms; plumbing, mechanical, and electrical work; new millwork and interior finishes in compliance with Ch. 8 of the 2015 IBC. Special inspections required per the attached Form 310 for anchors into existing construction. Canopies over windows are not included in this permit; a separate permit is required for the installation of the canopies. This building is NOT Fire Sprinklered**JAR**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice 8/18/20199/20/2019 DONE
mailed 9-23-19 with third and final follow up letter
Third Follow up  9/20/2019 DONE
Third Notice 7/15/20198/13/2019 DONE
mailed 8-13 with second follow up
Second Follow up  8/13/2019 DONE
Third Notice 6/15/20197/10/2019 DONE
mailed 7-11 with first follow up
First Follow up  7/10/2019 DONE
Third Notice 5/11/20196/10/2019 DONE
mailed 6-11
Third Notice 4/20/20195/6/2019 DONE
mailed 5-10-19
Second Notice 3/21/20194/15/2019 DONE
mailed 4-16-19
First Notice 3/4/20193/11/2019 DONE
mailed 3-12
BLD-Final2/22/20192/22/20192/22/2019PPASS
DetailsTony Young
Anthony Phone #: ###-####
Permanent Occupancy  2/22/2019 DONE
FIRE-Final Inspection2/21/20192/21/20192/21/2019PPASS
DetailsJim Page
Previously noted items have been corrected, final life fire safety inspection complete.

Anthony Phone #: ###-####
FIRE-Final Inspection2/20/20192/20/20192/20/2019PFAIL
DetailsJim Page
Provide exit signage and emergency lighting on the southside enclosed patio. Provide emergency lighting in corridor between restrooms. Provide signage over the top of the main entry reading "Door to remain unlocked while building is occupied". South door swings the wrong direction for path of travel, need to correct door swing and install panic type door hardware per building fire code review comments. Place fire extinguishers in discussed locations.

Anthony Phone #: ###-####
BLD-Framing/Rough-in2/5/20192/6/20192/6/2019APASS
DetailsTony Young
Anthony Phone #: ###-####,, exterior corner frame ok
BLD-Framing/Rough-in1/29/20191/30/20191/30/2019APART
DetailsTony Young
Antonio Phone #: ###-####,, rest room walls ok to cover,, all interior walls ok
Print Occupancy Form  1/11/2019 DONE
Permit Ready to Issue  1/11/2019 DONE
met
Telephone call  1/11/2019 DONE
Left message for Anthony informing permit is ready and the fee amount due for issuance
Issue PAID IN FULL permit  1/11/2019 DONE
Plan assigned to (JAR)11/30/201811/30/20181/10/2019 DONE
DetailsJulie Romig
01/11 - 2nd Rev - 1st Rev Comp - PAPER - L3 Dutch Goose
Pending Assignment by CDM11/29/2018 1/10/2019 PASS
DetailsCarl D Madsen
Routing - PLAN CHECK1/8/2019 1/10/2019 PASS
DetailsJulie Romig
Case Summary (BLD)  1/10/2019 DONE
PLANS/APPL TAKEN TO FRONT DESK  1/10/2019 DONE
Routing - Design Review1/8/2019 1/8/2019 PASS
DetailsKayCee Babb
Per plans updated to meet conditions of DRH18-00419.
Plan resubmittals received  1/7/2019 DONE
received response letter and two copies of email planning response and photos (6 pgs), lighting COM Check, and plan sheets G2.0, A1.1, A2.1, A5.1; taken to Julie Romig.
Route to Impact Fee Review12/26/201812/29/201812/26/2018 PASS
DetailsEric Bilimoria
Review requested for Commercial Permit
Routing - FIRE12/21/201812/24/201812/24/2018 PASS
DetailsErika Akin
Attached comments to case and plans
1st review completed  12/24/2018 FAIL
DetailsJulie Romig
Routing - PLAN CHECK11/30/2018 12/19/2018 FAIL
DetailsJulie Romig
Plan Review report emailed to applicant/architect.
Routing - PLUMBING12/6/2018 12/10/2018 PASS
DetailsDan Ediger
Per ISPC and the plans
Routing - MECHANICAL11/30/2018 12/6/2018 PASS
DetailsTroy James
Routing - Design Review11/30/2018 12/5/2018 FAIL
DetailsKayCee Babb
Corrections required per DRH18-00419. Stucco shall not extend below two feet above the ground plane, LED lighting details need to be provided to DR Staff for review, and paint colors of canopies and any other newly painted areas need to be provided to DR Staff for review.
Routing - PUBLIC WORKS11/30/2018 12/5/2018 PASS
DetailsMorgan Webb
Routing - Erosion and Sediment11/30/2018 12/5/2018 PASS
DetailsMichael Zawacki
No exterior work, no permit required.
Routing PW Environmental12/3/2018 12/4/2018 PASS
DetailsRick Christenson
Routing - Addressing11/30/2018 12/3/2018 PASS
DetailsDoug Chausow
Updated parcel number
Plans ACCEPTED BY PLAN TECH  11/29/2018 DONE
Intake Approval  11/29/2018 PASS
DetailsBrian McGowan
Recd Pcfee & Taken To Pln CK  11/29/2018 DONE
Application received 11/29/2018