BLD-Final | 10/23/2019 | 10/24/2019 | 10/24/2019 | A | PASS |
Tell Riley
|
|
|
Please call before. Phone #: ###-#### Inspection requested via web by Vaughn Pruett//approved plans provided//corrections made//upper kitchen moved to interior wall--only difference on plans//final complete per approved plans//
|
DOC - Permit Finaled | 10/24/2019 | 10/24/2019 | 10/24/2019 | P | PASS |
Tell Riley
|
|
|
|
BLD-Final | 10/17/2019 | 10/18/2019 | 10/18/2019 | A | FAIL |
Tell Riley
|
|
|
Please call before Phone #: ###-#### Inspection requested via web by Vaughn Pruett//correction notice issued//several items noted for code compliance//will need plans onsite for final as well//
|
BLD-Energy code compliance | 7/17/2019 | 7/17/2019 | 7/17/2019 | P | PART |
Tell Riley
|
|
|
Vaughn Phone #: ###-####//corrections made//designer printed new shear page--CS14 straps not needed//add insulation to wall between garage utility//
|
BLD-Framing/Rough-in | 7/12/2019 | 7/15/2019 | 7/15/2019 | A | PASS |
Tell Riley
|
|
|
Vaughn Phone #: ###-####//trusses ok//hold downs ok//add straps for shear walls per plans//ok to insulate only//
|
BLD-Framing/Rough-in | 7/11/2019 | 7/12/2019 | 7/12/2019 | A | FAIL |
Tell Riley
|
|
|
Vaugh Phone #: ###-####//add straps per plans//HDU anchors need 5" in concrete//need truss plans//correction notice posted..//
|
Override - Parcel Holds | 7/11/2019 | 1/1/1900 | 7/11/2019 | | |
|
|
|
this is not the final so insp ok
|
Routing - MECHANICAL | 7/8/2019 | | 7/8/2019 | | PASS |
Troy James
|
|
|
Manual j report. Back up heat source is a pellet stove and gas fireplace.
|
BLD-Wall Bracing | 6/10/2019 | 6/11/2019 | 6/11/2019 | A | FAIL |
Tell Riley
|
|
|
Vaughan Pruett Phone #: ###-####// no hold downs installed// obtain retro from designer for hold down install. call for re inspection.// ok to install house wrap. nailing ok per plans
|
BLD-Foundation | 5/1/2019 | 5/2/2019 | 5/2/2019 | P | PASS |
Jim Sly
|
|
|
Dustin-stem wall Phone #: ###-####
|
BLD-Footing | 4/26/2019 | 4/29/2019 | 4/29/2019 | A | PASS |
Jim Sly
|
|
|
Dustin Phone #: ###-####
|
Issue PAID IN FULL permit | | | 4/16/2019 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 4/16/2019 | | DONE |
|
|
|
|
Plan assigned to (JAB) Josh | 1/16/2019 | 1/16/2019 | 3/27/2019 | | PASS |
Josh Bogle
|
|
|
1/21 remodel, ePlan - 1st done
|
Routing - PLAN CHECK | 3/27/2019 | | 3/27/2019 | | PASS |
Josh Bogle
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/27/2019 | | DONE |
Josh Bogle
|
|
|
ESC yes - Energy yes
|
Permit Ready to Issue | | | 3/27/2019 | | DONE |
|
|
|
NEED
RP
|
Routing - PLANNING | 3/26/2019 | | 3/26/2019 | | PASS |
Sue Cummings
|
|
|
O.K. now
|
Plan Reviewer's activity | | | 3/26/2019 | | DONE |
Josh Bogle
|
|
|
left msg for Vaughn asking about beam sizes - plans may have a glitch that is making them illegible
|
Routing - PLANNING | 3/14/2019 | | 3/14/2019 | | FAIL |
Sue Cummings
|
|
|
ROS #11731 combines the percels into one. Back up area concrete need to be 3 ft. from PL
|
Routing - PLAN CHECK | 3/14/2019 | | 3/14/2019 | | FAIL |
Josh Bogle
|
|
|
beams innadequate
|
Routing - PLANNING | 2/14/2019 | | 2/15/2019 | | FAIL |
Sue Cummings
|
|
|
The ROS has not yet been completed. Needs to show approach the new garage
|
Routing - PLAN CHECK | 2/14/2019 | | 2/15/2019 | | FAIL |
Josh Bogle
|
|
|
see e-mail 2.15.19
|
Plan Reviewer's activity | | | 2/14/2019 | | DONE |
Josh Bogle
|
|
|
accepted resubmittal - inquired with LTL about ROS
|
1st review completed | | | 1/16/2019 | | FAIL |
Josh Bogle
|
|
|
|
Routing - PLAN CHECK | 1/15/2019 | | 1/16/2019 | | FAIL |
Josh Bogle
|
|
|
see e-mail to Vaughn 1.16.19
|
Intake Approval | | | 1/15/2019 | | PASS |
|
|
|
|
Intake Approval | | | 1/14/2019 | | FAIL |
|
|
|
Site plan must include both parcels with set backs. The current site plan implies the new addition encroaches on unknown property. Also, make sure that the setback distances import clearly and are readable.
|
Intake Approval | | | 1/11/2019 | | FAIL |
|
|
|
Please upload all plan sheets individually
|
Application received | | | 1/10/2019 | | DONE |
|
|
|
Application submitted via PDS Online on Jan 10 2019 5:27PM
|
Routing - PLANNING | 1/16/2019 | | | | FAIL |
|
|
|
Two kitchens are not allowed.
|