Information based on query as of Sunday, May 19, 2024.
Permit Information
Permit NumberBLD19-01355
StatusFinaled
Name COASTAL CONSTRUCTION AND LUMBER COM
Site Address 11201 W GABRIELLE DR
Project NameGalahad Townhouses Sevenplex
Customer NumberBLD19-01355, 01358 - 01363
ePlanReviewYes
Description
**PASSES USING UA TRADE OFF** (SEVEN PERMITS IN EPLAN UNDER BLD19-01355) Permit for the construction of a new 1157 sq. ft., two story (first story 543 sq. ft., second story 614 sq. ft.) single family dwelling with 2 bedrooms, 2.5 bathrooms, approximately 40 sq. ft. of covered patio/porch per the approved plans and any notations. C-2 D/DA zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/20/201912/20/201912/20/2019PPASS
DetailsMike Jordan
Kenny Phone #: ###-####
DOC - Permit Finaled12/20/201912/20/201912/20/2019PPASS
DetailsMike Jordan
BLD-Blower Door Test Results12/20/201912/20/201912/20/2019PDONE
DetailsMike Jordan
5.7
BLD-Energy code compliance10/2/201910/3/201910/3/2019APASS
DetailsMike Jordan
Kenny Phone #: ###-####. All issues have been resolved.
BLD-Energy code compliance10/1/201910/1/201910/1/2019PCANC
DetailsMike Jordan
Cancelled by contractor via text message.
BLD-Energy code compliance9/30/201910/1/201910/1/2019ACANC
DetailsMike Jordan
KENNY Phone #: ###-####. Moved to pm inspection.
BLD-Framing/Rough-in9/27/20199/30/20199/30/2019APART
DetailsMike Jordan
Kenny Phone #: ###-####. Provide approved fix for cut top chords of floor joist at plumbing penetrations. Complete fire cauliking. complete laydown parapet in noted areas. Install mised lateral bracing.
BLD-Wall Bracing9/6/20199/6/20199/6/2019PPASS
DetailsMike Jordan
KENNY Phone #: ###-####
BLD-Other8/23/20198/23/20198/23/2019PPASS
DetailsMike Jordan
Kenny- insalation for fire wall Phone #: ###-####
BLD-Energy code compliance8/9/20198/9/20198/9/2019PPASS
DetailsMike Jordan
LARRY Phone #: ###-####. Insulation for 1hr. walls first floor.
Plan Reviewer's activity  8/9/2019 DONE
DetailsJenny Nelson
Appllicant called and wanted to cancel plan mod request, said they built to approved plans and did not make changes. Are going to make changes on other townhouses in subdivision, will submit plan mod for those.
Telephone call  8/9/2019 DONE
Larry with Sterling Home cancel the plan mod for ALL 7 townhomes per Jenny this is okay to cancel.
CHANGE STATUS TO (ISS)  8/9/2019 DONE
plan mod cancel by Larry from Sterling Homes okay to do per Jenny.
Plan Modification Accepted  8/1/2019 DONE
At request of applicant, plan mod workflow started for changes to interior wall gypsum and fire-rated wall assembly.
BLD-Concrete7/24/20197/26/20197/26/2019PPART
DetailsTell Riley
rebar-Shane Phone #: ###-####//rebar inspected on AM inspection//maintain clearances//
BLD-Foundation7/25/20197/26/20197/26/2019APART
DetailsTell Riley
Kenny Phone #: ###-####//extend vapor barrier to edge of foundation//maintain rebar clearance//
BLD-Footing6/25/20196/25/20196/25/2019PCANC
DetailsMike Jordan
Kenny- Phone #: ###-####
BLD-Energy code compliance6/25/20196/25/20196/25/2019PPASS
DetailsMike Jordan
Kenny- Phone #: ###-####. Rigid insulation on stemwall under slab on grade.
BLD-Foundation6/19/20196/20/20196/20/2019PPART
DetailsMike Jordan
Dane- inspection wall Phone #: ###-####
BLD-Footing6/18/20196/19/20196/19/2019PPART
DetailsMike Jordan
Dane Phone #: ###-####
Issue PAID IN FULL permit  5/29/2019 DONE
Inspection Record Card- Bld  5/29/2019 DONE
OVERRIDE  5/24/2019  
Plan assigned to (J_N)5/15/20195/15/20195/24/2019 DONE
DetailsJenny Nelson
06/03 townhouses L2 ePlan
Routing - PLAN CHECK5/15/2019 5/24/2019 PASS
DetailsJenny Nelson
1st review completed  5/24/2019 DONE
DetailsJenny Nelson
PLANS/APPL TAKEN TO FRONT DESK  5/24/2019 DONE
DetailsJenny Nelson
Permit Ready to Issue  5/24/2019 DONE
met
DO NOT ISSUE WITHOUT BLD19-01355, BLD19-01358 TO BLD19-01363
Route to Impact Fee Review5/15/20195/18/20195/16/2019 PASS
DetailsShannon Cade
Initial residential review of new SFD permits requested for now.
Routing - PUBLIC WORKS5/15/2019 5/16/2019 PASS
DetailsAngela Hardy
Routing - MECHANICAL5/15/2019 5/16/2019 PASS
DetailsChad Schwendiman
Routing - PLANNING5/15/2019 5/16/2019 PASS
DetailsAndrea Tuning
Routing - Addressing5/15/2019 5/15/2019 PASS
DetailsDoug Chausow
Plans ACCEPTED BY PLAN TECH  5/15/2019 DONE
Intake Approval  5/15/2019 PASS
Recd Pcfee & Taken To Pln CK  5/15/2019 DONE
Intake Approval  5/7/2019 FAIL
Adam uploaded the res check so we still need manual J's
Intake Approval  5/7/2019 FAIL
5-7-19 Adam, Spoke with Chad (mechanical supervisor) and he stated that the typical manual J (ACCA Report) has to be submitted. Cannot accept HAVC Load Calcs. If you have any questions please contact him at ###-####
Meeting  4/29/2019 DONE
Spoke with Larry with Sterling Homes, he informed me that Cosatal Construction and Lumber is the parent company and is the RCE number they will be using.
Intake Approval  4/25/2019 FAIL
A manual J is required for each unit.
Please email a GC form with an RCE number that corresponds with the company of record to: permits@cityofboise.org. Please reference the building permit in the subject line.
Application received  4/23/2019 DONE
Application submitted via PDS Online on Apr 23 2019 4:33PM