Permit Information
Permit NumberBLD20-00153
StatusFinaled
Name CBH HOMES
Site Address 10068 W CAMPVILLE ST
Project NameLOT 30 BLK 01 UNION SQUARE SUB
Customer Number 
ePlanReviewYes
Description
**PRESCRIPTIVE ENERGY REQUIREMENT**Permit for the construction of a new 2530 sq. ft., two story (first story 1088 sq. ft., second story 1442 sq. ft.) single family dwelling with 4 bedrooms, 2.5 bathrooms, approximately 91 sq. ft. of covered patio/porch and a 645 sq. ft. attached garage per the approved plans and any notations. R-2D zoning and setbacks per planning. D_S
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/2/20206/3/20206/3/2020APASS
DetailsDave Hannah
Front door is open Phone #: ###-#### Inspection requested via web by Joel Hirtle
DOC - Permit Finaled6/3/20206/3/20206/3/2020PPASS
DetailsDave Hannah
BLD-Final6/1/20206/1/20206/1/2020PNR
DetailsTell Riley
Front door is open Phone #: ###-#### Inspection requested via web by Joel Hirtle//plans on counter show smoke/CO combo outside den on first floor--only smoke was installed//
BLD-Final5/27/20205/28/20205/28/2020PNR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Needs mech final.
BLD-Energy code compliance4/9/20204/10/20204/10/2020APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD-Energy code compliance4/8/20204/9/20204/9/2020PCANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
BLD-Framing/Rough-in4/7/20204/8/20204/8/2020PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD-Framing/Rough-in4/7/20204/8/20204/7/2020ACANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
BLD-Framing/Rough-in4/1/20204/6/20204/6/2020ANR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Needs electrical rough in inspection.
BLD-Framing/Rough-in4/1/20204/1/20204/1/2020PCANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Joel Hirtle Inspection cancelled from web by: Joel Hirtle
BLD-Framing/Rough-in3/27/20203/30/20203/30/2020ANR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Joel Hirtle. Needs MEP's.
BLD-Wall Bracing3/23/20203/24/20203/24/2020APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Joel Hirtle
Fees Due Hold3/6/2020 3/10/2020 DONE
Details
Routing - MECHANICAL3/4/2020 3/5/2020 PASS
DetailsTroy James
Plan Modification Accepted  3/3/2020 DONE
Plan Mod Manual J per CBH Homes Gloria Martinez
BLD-Foundation2/25/20202/26/20202/26/2020PPART
DetailsMike Jordan
Dane Phone #: ###-####
BLD-Footing2/24/20202/25/20202/25/2020PPART
DetailsMike Jordan
Jerry Phone #: ###-####
Issue PAID IN FULL permit  2/6/2020 DONE
Inspection Record Card- Bld  2/6/2020 DONE
Telephone call  2/6/2020 DONE
Email permits to be sign to - permitting@cbhhomes.com EPLAN will need to be release
OVERRIDE  2/5/2020  
Permit Ready to Issue  2/5/2020 DONE
met
Plan assigned to (D_S) Debbie1/30/20201/30/20202/4/2020 DONE
DetailsDebbie Sanine
Routing - PLAN CHECK1/30/2020 2/4/2020 PASS
DetailsJenny Nelson
1st review completed  2/4/2020 DONE
DetailsDebbie Sanine
PLANS/APPL TAKEN TO FRONT DESK  2/4/2020 DONE
DetailsDebbie Sanine
Meeting  2/4/2020 DONE
In correct total sq ft was not put on the application. Total sq ft should be 2530 and not 1088. Correct the sq ft. Total value should be 294,340.20 for 2530 and not 126.577.92 for 1088. TCH
Route to Impact Fee Review1/30/20202/2/20201/31/2020 PASS
DetailsTravis P Black
Initial residential review of new SFD permits requested for now.
Routing - MECHANICAL1/30/2020 1/31/2020 PASS
DetailsTroy James
Routing - PLANNING1/30/2020 1/31/2020 PASS
DetailsSue Cummings
Routing - Addressing1/30/2020 1/31/2020 PASS
DetailsDoug Chausow
Routing - PUBLIC WORKS1/30/2020 1/31/2020 PASS
DetailsMorgan Webb
Plans ACCEPTED BY PLAN TECH  1/30/2020 DONE
Recd Pcfee & Taken To Pln CK  1/30/2020 DONE
Intake Approval  1/30/2020 PASS
Intake Approval  1/23/2020 FAIL
2nd prescreen: Please correct the address on your Manual J, you corrected the lot and block but the city is not correct, it cannot say "Meridian" Thank you
Intake Approval  1/17/2020 FAIL
1st prescreen: Please provide a manual J with the correct address or lot and block; please provide an application with the correct square footage; move the sod stamp out of the bottom right corner per ePlan submittal standards; please provide exterior materials.
Application received  1/16/2020 DONE
Application submitted via PDS Online on Jan 16 2020 3:33PM