Final | 4/7/2020 | 4/8/2020 | 4/8/2020 | P | PASS |
Brian Scoles
|
|
|
GARAGE CODE: 4343 Phone #: ###-#### Inspection requested via web by Kristy Watson- final ok
|
Mec-Aging Inspection | 4/7/2020 | 4/7/2020 | 4/7/2020 | | FAIL |
Brian Scoles
|
|
|
texted contractor to check in on this aging permit
|
Final | 1/7/2020 | 1/8/2020 | 1/8/2020 | A | FAIL |
Brian Scoles
|
|
|
GARAGE CODE: 4343 Phone #: ###-#### Inspection requested via web by Kristy Watson- need locking caps on service ports on a/c- need uv protection on lineset at a/c- need to remove stucco around gas pipe and seal- need air balance report onsite- duct blast test needs completed
|
Mec-Aging Inspection | 1/7/2020 | 1/7/2020 | 1/7/2020 | | FAIL |
Brian Scoles
|
|
|
needs called in for final inspection-WIP
|
Rough-in | 6/26/2019 | 6/26/2019 | 6/26/2019 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson- R/I ok
|
Rough-in | 6/19/2019 | 6/19/2019 | 6/19/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson- corrections not all made- supply duct in crawl still needs 4" clearance off ground at crawl hole location
|
Rough-in | 6/17/2019 | 6/17/2019 | 6/17/2019 | P | FAIL |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson 1- duct in crawl needs minimum 4" clearance off ground 2- b vent at roof needs 1" clearance to combustibles laying against plywood sheathing 3- need to seal all spot welds on supply and return boots 4- need to seal dryer duct to termination box in wall 5- need to resubmit man J to city for approval and have approved man j onsite with equipment brand installed- shows payne and has bryant installed
left correction notice front window
|
Pressure Test | 6/17/2019 | 6/17/2019 | 6/17/2019 | P | PASS |
Brian Scoles
|
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson- 20lb gas pass tagged meter location
|
Issue PAID IN FULL permit | | | 6/17/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/17/2019 | | DONE |
|
|
|
This permit was created on the web by Kristy Watson
|