Permit Information
Permit NumberBLD17-03009
StatusFinaled
Name ENERGREEN DEVELOPMENT COMPANY LLC
Site Address 1502 W RIVER ST
Project Name15th & River St Condos Bldg 1
Customer NumberBLD17-03010 GRD18-00032
ePlanReviewYes
Description
(2 PERMITS FILED UNDER BLD17-03009 IN EPLANREVIEW)(15TH & RIVER CONDOMINIUMS - BLDG 1) **Permit for the construction of a 3-story 5-unit concrete and wood framed apartment building with work to include general site work and construction of the new building per the approved plans. Special inspections required per attached Form 310. This building is fully fire sprinklered with an NFPA 13-R system. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/17/20203/17/20203/19/2020PPART
DetailsDave Hannah
Tim - Inspection for Temporary Occ Phone #: ###-#### ok for tco
FIRE-Final Inspection3/18/20203/19/20203/19/2020APASS
DetailsJim Page
Previously noted items have been corrected, fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguishers are placed with current inspection tags. Final life fire safety inspection complete, signature card not available at time of inspection.

Tim Phone #: ###-####
FIRE-Final Inspection3/18/20203/18/20203/18/2020PFAIL
DetailsJim Page
Fire riser room is not a rated room as required by Boise Municipal Code, Chapter 7 Fire Prevention Code section 903.1.2. Provide building permit fire review comments for project, documents are required to be onsite, per conversation with point of contact they are not onsite. Install addressing that is compliant with 2016 IFC section 505, current addressing does not meet the requirements of section 505. Provide corner lot addressing as defined in the BMC Chapter 7 section 505.3. Provide fire extinguishers with current inspection tags for each unit, fire extingiushers can be mounted under the sink. Correct the addressing with the monitoring company.

Tim Phone #: ###-####
BLD-Conference1/6/20201/6/20201/7/2020PDONE
DetailsDave Hannah
Tim Phone #: ###-####
BLD-Energy code compliance11/12/201911/13/201911/13/2019APASS
DetailsDave Hannah
Units 106, 107, 108 - Curt Phone #: ###-####
BLD-Framing/Rough-in11/4/201911/5/201911/5/2019PPASS
DetailsDave Hannah
Unit 106 - Curt Phone #: ###-####
BLD-Energy code compliance11/4/201911/5/201911/5/2019APASS
DetailsDave Hannah
Unit 109 and 110 - Curt Phone #: ###-####
BLD-Framing/Rough-in11/1/201911/4/201911/4/2019PPASS
DetailsDave Hannah
units 106 & 107 // Kurt Phone #: ###-#### unit 107 only
BLD-Framing/Rough-in10/24/201910/28/201910/28/2019PPASS
DetailsDave Hannah
unit 108 only // Curt Phone #: ###-####
BLD-Framing/Rough-in10/17/201910/18/201910/18/2019APASS
DetailsMike Jordan
Kirt Phone #: ###-####. Unit 109 only.
BLD-Framing/Rough-in10/11/201910/11/201910/11/2019PPEND
DetailsBrandon Shaw
Pending PLM rough-in approval...
BLD-Foundation4/25/20194/25/20194/26/2019PPASS
DetailsDave Hannah
Tim Phone #: ###-####third floor center walls ok
BLD-Foundation4/15/20194/15/20194/16/2019PPART
DetailsDave Hannah
Tim Phone #: ###-#### third floor ext walls ok
BLD-Foundation2/11/20192/11/20192/12/2019PPASS
DetailsDave Hannah
Tim Phone #: ###-#### second level and ext stair north bld and south stair
BLD-Footing12/20/201812/21/201812/21/2018APASS
DetailsDave Hannah
Tim Phone #: ###-####
BLD-Foundation12/19/201812/20/201812/20/2018APASS
DetailsDave Hannah
wall-tim Phone #: ###-#### first floor center walls
BLD-Footing12/11/201812/12/201812/12/2018APART
DetailsDave Hannah
wall // tim Phone #: ###-#### first level north building
BLD-Foundation12/10/201812/10/201812/10/2018PNR
DetailsMike Jordan
Tim Phone #: ###-####
BLD-Foundation9/21/20189/21/20189/21/2018PPART
DetailsDave Hannah
pouring at 3:30 Tim Phone #: ###-#### walls between units ok
BLD-Foundation9/20/20189/20/20189/20/2018PPART
DetailsDave Hannah
Tim-pour time 3:00 Phone #: ###-#### first 4 ft ok
BLD-Footing9/11/20189/11/20189/11/2018PPASS
DetailsDave Hannah
Pour at 3 // Tim Phone #: ###-####