Permit Information
Permit NumberBLD18-02473
StatusFinaled
Name ACNS LLC
Site Address 410 S ORCHARD ST Unit: 108
Project NameEscape this Live Boise Ste 108
Customer NumberBLD17-03056 EPLAN
ePlanReviewNo
Description
(ESCAPE THIS LIVE BOISE) **This building is not Fire Sprinklered. Permit for tenant improvements to a 1,744 sq ft existing office, Suite 108. Tenant will also be occupying the adjacent 1,744 sq ft existing building, Suite 104, under BLD17-03056. Work to include: infilling the illegal opening in the 1-hour fire wall at the property line between the two building suites for code compliance; new door hardware. Details provided in the approved documents for the 1-hour fire wall infill are based on the original permit drawings of a similar condition. Field verify new construction matches existing and the rating is maintained. All interior finishes are to be in compliance with Ch. 8 of the 2012 IBC. All work to be done per the approved plans and applicable codes and ordinances. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/22/20201/22/20201/22/2020PPASS
DetailsTell Riley
call ahead -Sherry Phone #: ###-####//no inspection card to sign//final complete per scope of work//door hardware changed//
FIRE-Final Inspection1/22/20201/22/20201/22/2020PPASS
DetailsTroy Cobbley
Life safety passed.

call ahead -Sherry Phone #: ###-####
FIRE-Final Inspection10/3/201910/4/201910/4/2019PFAIL
DetailsTroy Cobbley
Remove the thumbturn deadbolt at the main exit (keyed ok), provide annual inspection for the fire extinguishers, mount the fire extinguishers no higher than 5', remove the chain/padlock from door as per discussion.


Sherry Phone #: ###-####
FIRE-Final Inspection10/2/201910/2/201910/3/2019PFAIL
DetailsTroy Cobbley
Provide city approved package/drawings. I noted thumbturn deadbolt on main exit and expired fire extinguishers.

SHERRY Phone #: ###-####
BLD-Final10/1/201910/1/201910/1/2019PPART
DetailsTell Riley
NO ELE WORK PER JULIE R // cheri Phone #: ###-####//need fire life safety//
BLD-Wall cover9/11/20199/11/20199/11/2019PPASS
DetailsTell Riley
Request for inspection for prior to wall cover, was asked by client to close opening in room. Framing, drywall etc Phone #: ###-#### Inspection requested via web by Neil Smart//will maintain existing rating on fire wall//hardware will be replaced prior to final//