Information based on query as of Thursday, May 16, 2024.
Permit Information
Permit NumberBLD18-04023
StatusFinaled
Name DOUG LASHER CONSTRUCTION
Site Address 4009 W EDGEMONT ST
Project NameParson's residence
Customer Number 
ePlanReviewNo
Description
**PASSES UA TRADE OFF METHOD** Permit for the construction of a new 2895 sq. ft., two story (first story 1851 sq. ft., second story 1044 sq. ft.) single family dwelling with 4 bedrooms, 3 bathrooms, approximately 432 sq. ft. of covered patio/porch and a 778 sq. ft. attached garage per the approved plans and any notations. R-1C zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/11/20194/12/20194/12/2019APASS
DetailsBrandon Shaw
Garage code s 1905 help yourself Phone #: ###-#### Inspection requested via web by bryan murdoch
DOC - Permit Finaled4/12/20194/12/20194/12/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results4/12/20194/12/20194/12/2019ADONE
DetailsBrandon Shaw
ACH50- 2.87
BLD-Framing/Rough-in1/24/20191/25/20191/25/2019APASS
DetailsDave Hannah
Thanks Inspection requested via web by bryan murdoch
BLD-Energy code compliance1/24/20191/25/20191/25/2019APASS
DetailsDave Hannah
Thanks Inspection requested via web by bryan murdoch
BLD-Framing/Rough-in1/23/20191/23/20191/23/2019PFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by bryan murdoch. Install all missing straps on portal frames. Install additional 2x6 studs under C01 3 ply at bearing point. Install the SDS screws on the 3ply C01 truss as shown on the truss engineering. Ok to insulate.
BLD-Wall Bracing12/19/201812/21/201812/21/2018APART
DetailsBrandon Shaw
First floor only...
Vertical straps at port hole framing to be installed befotre framing rough-in...
BLD-Foundation11/19/201811/20/201811/20/2018APASS
DetailsDave Hannah
Eric Williams Phone #: ###-####
BLD-Footing11/16/201811/16/201811/16/2018PPASS
DetailsDave Hannah
Eric Phone #: ###-####