Permit Information
Permit NumberBLD18-04113
StatusFinaled
Name INTERMOUNTAIN PROPERTY DEVELOPMENT
Site Address 3858 N GARDEN CENTER WAY Unit: STE 102
Project NameVitam PT - Office Expansion
Customer Number 
ePlanReviewYes
Description
(VITAM PHYSICAL THERAPY) Permit is to expand their existing office from a 1,070-square foot office space into 2,122-square foot office. Original permit for office was issued under BLD13-03203. Approval contingent upon adhering to the approved plans on file. Work to include: demolition of existing partition walls/doors, construction of interior non-combustible full height partition walls, reception area, four treatment rooms, two storage closets, two open exercise rooms, new light switching, new accessible doors / hardware, installation of ducts and diffusers, installation of new millwork, installation of 3 new sinks, and finishes in compliance with chapter 8 of the 2015 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JHB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/27/20192/27/20192/27/2019PPASS
DetailsTony Young
Dan Phone #: ###-####
FIRE-Final Inspection2/26/20192/27/20192/27/2019APASS
DetailsJim Page
Fire sprinkler inspection is complete, fire alarm inspection is complete, fire extinguisher is placed with a current inspection tag. Final life fire safety inspection for area of work complete.

Dan Phone #: ###-####
FIRE-Final Inspection2/25/20192/26/20192/26/2019PCANC
DetailsJim Page
Cancelled per conversation with point of contact, will be rescheduled after emergency lighting matches city approved drawings.

please call Dan for access Phone #: ###-####
FIRE-Final Inspection2/19/20192/20/20192/20/2019AFAIL
DetailsJim Page
FIR permit (FIR18-00963) for fire alarms is still in issued status during the time of entering these notes, FIR permit for fire alarms needs to be completed before life fire safety can be finaled.

Call 20 minutes before // Dan Phone #: ###-####
BLD-Conference2/1/20192/4/20192/8/2019APART
DetailsTony Young
Dan-please call 20 minutes prior to meet Phone #: ###-####,, ?s on ADA
BLD-Ceiling Grid Inspection2/8/20192/8/20192/8/2019PPART
DetailsTony Young
Dan- please call 20 min ahead Phone #: ###-####,, ok pending trades
BLD-Wall Bracing1/8/20191/9/20191/9/2019APASS
DetailsTony Young
Dan Phone #: ###-####,, walls ok to cover