Information based on query as of Saturday, May 18, 2024.
Permit Information
Permit NumberBLD19-01678
StatusFinaled
Name TED MASON SIGNATURE HOMES INC
Site Address 5577 N MISTY RIDGE WAY
Project Name 
Customer Number 
ePlanReviewNo
Description
***08/21/19 PLAN MODIFICATION TO ADD 2 WINDOWS, 1 ON EACH SIDE OF FIREPLACE*** Permit for the construction of a new 2388 sq. ft., one story single family dwelling with 4 bedrooms, 2.5 bathrooms, approximately 304 sq. ft. of covered patio/porch and a 1231 sq. ft. attached garage per the approved plans and any notations. H.E.R.S. testing will be performed and Prescriptive Energy Compliance is specified. R-1C zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Blower Door Test Results12/18/201912/18/201912/18/2019ADONE
DetailsTell Riley
3.06 ACH 50
BLD-Final12/17/201912/18/201912/18/2019APASS
DetailsTell Riley
Call for access Phone #: 2086089669 >> Inspection requested via mobile web by Nate Mason//corrections made//
DOC - Permit Finaled12/18/201912/18/201912/18/2019PPASS
DetailsTell Riley
BLD-Final12/12/201912/13/201912/13/2019AFAIL
DetailsTell Riley
Call for access Phone #: 2086089669 >> Inspection requested via mobile web by Nate Mason//need to fix hole in ceiling in mechanical area//add 3x3 landing at front entry door--step over 8" max allowed 7 3/4"//clean up construction debris//adjust self closing hinges to shut door all the way on garage man door//
BLD-Wall Bracing9/24/20199/25/20199/25/2019APASS
DetailsTell Riley
Phone #: 2086089669 >> Inspection requested via mobile web by Nate Mason//interior shear --ok//
BLD-Energy code compliance9/16/20199/17/20199/17/2019APASS
DetailsTell Riley
Phone #: 2086089669 >> Inspection requested via mobile web by Nate Mason
BLD-Framing/Rough-in9/12/20199/13/20199/13/2019APASS
DetailsTell Riley
Phone #: 2086089669 >> Inspection requested via mobile web by Nate Mason//corrections made and information provided//
BLD-Framing/Rough-in9/10/20199/11/20199/11/2019AFAIL
DetailsTell Riley
Phone #: 2086089669 >> Inspection requested via mobile web by Nate Mason//add truss bracing// SDWC screws--a moajority of them are not installed correctly//correction notice onsite//
BLD-Wall Bracing8/7/20198/8/20198/8/2019APASS
DetailsTell Riley
Danny Phone #: ###-####//nailing on exterior walls only//check holddowns on portal frame at framing///
BLD-Footing7/8/20197/8/20197/8/2019PPASS
DetailsTell Riley
JR Phone #: ###-####//rebar installed per plans//side and front setbacks per plans//rear setback is tight to line--discussed onsite --6" pop-out to be at 15' setback at foundation inspection//call for foundation inspection//