Permit Information
Permit NumberBLD19-01682
StatusFinaled
Name DEBELLOY CONSTRUCTION
Site Address 9056 W EMERALD ST
Project NameGyro Shack
Customer Number 
ePlanReviewYes
Description
(GYRO SHACK) To construct a 4,673 sq. ft. single story commercial building (1,588 sq. ft. + 3,085 sq. ft. tenant shell space) for use as a restaurant and related site improvements. Approval is contingent upon adhering to the approved plans on file, DRH18-00543, attached engineering and plan review report. Scope of work includes: site work, construction of a slab on grade, concrete foundation, construction of stud framed exterior envelope walls with stucco and split face masonry veneer finish, 2-hour fire barrier interior tenant demising wall, pre-engineered roof wood truss system, Type 1 hood, electrical work, mechanical work and plumbing work. No occupancy is allowed under this permit for future floor shell tenant area, a separate tenant improvement permit is required for occupancy of the future shell floor tenant space. Note 1: canopies/awnings not part of the scope of work, canopy/awnings shall be a separate permit. Note 2: Special inspection is required, see attached 310 form. This building is Not Fire Sprinklered. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/16/201912/17/201912/17/2019PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Shawn Plimmer. Ok for temp occ. Will be ok for perm occ. once zoning signs perm.
BLD-Final12/13/201912/16/201912/16/2019PNR
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Shawn Plimmer. Evrything ok. Needs public works final.
BLD-Ceiling Grid Inspection12/13/201912/13/201912/13/2019PDONE
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Shawn Plimmer
FIRE-Final Inspection12/13/201912/13/201912/13/2019PPASS
DetailsTroy Cobbley
Life safety passed. Phone #: ###-#### Inspection requested via web by Shawn Plimmer
BLD-Final12/11/201912/12/201912/12/2019PCANC
DetailsMike Jordan
Shawn Phone #: ###-####
FIRE-Final Inspection12/11/201912/12/201912/12/2019AFAIL
DetailsTroy Cobbley
Need the project related FIR permit addressed, need address numbers on the street side of the building, need occupant load sign, need to remove the exit signs in the island restroom corridor as discussed, need to mount the fire extinguishers as discussed.

Shawn Phone #: ###-####
BLD-Ceiling Grid Inspection12/6/201912/9/201912/9/2019APART
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Shawn Plimmer. Ceiling grid pending elec. rough in inspection.
BLD-Other10/29/201910/29/201910/29/2019APASS
DetailsMike Jordan
Fire wall layer 2 inspection Phone #: ###-#### Inspection requested via web by Shawn Plimmer
BLD-Wall cover10/23/201910/23/201910/23/2019APASS
DetailsMike Jordan
Fire wall layer one inspection Phone #: ###-#### Inspection requested via web by Shawn Plimmer. Base layer 5/8 type X rock ok.
BLD-Energy code compliance10/16/201910/17/201910/17/2019PPASS
DetailsMike Jordan
Look at framing remarks as well as energy. Call Shawn 2088013772 Phone #: ###-#### Inspection requested via web by Shawn Plimmer
BLD-Framing/Rough-in10/17/201910/17/201910/17/2019PPASS
DetailsMike Jordan
Look at framing remarks as well as energy. Call Shawn 2088013772 Phone #: ###-#### Inspection requested via web by Shawn Plimmer
BLD-Framing/Rough-in10/14/201910/14/201910/14/2019AFAIL
DetailsMike Jordan
Call Shawn prior. 2088013772 Phone #: ###-#### Inspection requested via web by Shawn Plimmer. Provide additional studs under 2 and 3 ply girder trusses. Nail off girder trusses per the engineering. fire block concealed space at roof drain. Ok to insulate.
BLD-Other9/18/20199/19/20199/19/2019ACANC
DetailsMike Jordan
Call prior to going Phone #: 2088013772 >> Inspection requested via mobile web by Shawn Plimmer
BLD-Wall Bracing9/19/20199/19/20199/19/2019APASS
DetailsMike Jordan
Call prior to going Phone #: 2088013772 >> Inspection requested via mobile web by Shawn Plimmer. Exterior perimeter walls and roof ok.
BLD-Other8/8/20198/9/20198/9/2019ACANC
DetailsMike Jordan
Seepage bed has been excavated to free draining material. Need any city inspection if required. Phone #: ###-#### Inspection requested via web by Shawn Plimmer
BLD-Foundation8/8/20198/8/20198/8/2019PPART
DetailsMike Jordan
Late afternoon if possible. Thanks Phone #: ###-#### Inspection requested via web by Shawn Plimmer. Perimeter stemwall. Need RFI from engineer of record accepting offset placement of column pad footings.
BLD-Foundation8/8/20198/8/20198/8/2019ACANC
DetailsMike Jordan
Late afternoon if possible. Phone #: ###-#### >> Inspection requested via web by Shawn Plimmer Inspection cancelled from web by: Shawn Plimmer
BLD-Footing8/5/20198/6/20198/6/2019APART
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Shawn Plimmer. Perimeter footings. Noted that SE footing was not the required 24inch width. Work in progress on repair. Ok to place concrete. Will verify footing width on stemwall inspection.
BLD-Footing8/5/20198/5/20198/5/2019PNR
DetailsMike Jordan
3:30pm please-James Phone #: ###-####