Permit Information
Permit NumberBLD19-02238
StatusFinaled
Name ESI
Site Address 600 N MILWAUKEE ST
Project NameMOD Pizza - Restaurant
Customer NumberBLD19-02463
ePlanReviewYes
Description
(MOD PIZZA – RESTAURANT – SOUTH END) (DRH18-00522) The fire sprinkler system is used for fire area. This permit shall not be issued until permit BLD19-02463 is issued (aforementioned permit issued 8/8/19 GF). To construct improvements for a new restaurant tenant within an existing 3,090 square foot shell tenant space. This building was formerly occupied by “TGI Friday’s” restaurant. Work is to include interior nonbearing walls, two toilet rooms accessible to the disabled, booths, tables, chairs, kitchen equipment, a walk-in cooler/freezer, a direct vent pizza oven, a suspended acoustical ceiling, gypsum board ceilings, and finishes. A new gate will be installed in an exterior fence to swing in the direction of egress travel from an exterior patio area along an egress path from the restaurant. Structural work is to include modifications to two interior shear walls to maintain or restore their capacity to resist lateral loads (wood structural sheathing, sill anchors, hold downs, drag strut, and beam). Special Inspection is required for welding and for post-installed anchors in hardened concrete. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/7/201911/8/201911/8/2019APASS
DetailsDave Hannah
Chris Phone #: ###-####
FIRE-Final Inspection11/6/201911/7/201911/7/2019APASS
DetailsTroy Cobbley
Life safety passed.

Chris Phone #: ###-####
BLD-Ceiling Grid Inspection10/28/201910/29/201910/29/2019APASS
DetailsMike Jordan
Chris Phone #: ###-####
BLD-Ceiling Grid Inspection10/15/201910/16/201910/16/2019PPASS
DetailsMike Jordan
chris Phone #: ###-####
BLD-Wall Bracing10/10/201910/11/201910/11/2019APART
DetailsTell Riley
Chris Phone #: ###-####//shear wall nailing ok per plans//hold downs and welding required for shear walls completed by third party//ok to cover pending third party approval of hold downs installation//
BLD-Ceiling Grid Inspection10/4/201910/7/201910/7/2019APART
DetailsJim Storey
Chris Phone #: ###-#### hardlids in bathrooms ok/ kicker at soffit instaled perplan.
BLD-Framing/Rough-in10/3/201910/4/201910/4/2019PNR
DetailsMike Jordan
Chris Phone #: ###-####. Hardlids in restrooms ok, Needs to add kickers to drop soffit over beverage area, also needs fire sprinkler rough in inspection as well.
BLD-Energy code compliance9/30/201910/1/201910/1/2019APASS
DetailsMike Jordan
Restroom and cooler walls ok.
BLD-Energy code compliance9/27/20199/30/20199/30/2019ANR
DetailsMike Jordan
Chris Phone #: ###-####.
BLD-Framing/Rough-in9/26/20199/27/20199/27/2019APART
DetailsTell Riley
Chris Phone #: ###-####//ok to cover bathroom walls only//need shearwalls to reflect plans--anchoring, posts,mechanical connections and shear nailing//need mechanical inspection for ceilings//