Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberBLD19-03111
StatusFinaled
Name TRESIDIO HOMES
Site Address 1771 S KIMBALL WAY
Project NameMC 11-1
Customer Number 
ePlanReviewYes
Description
Permit for the construction of a new 2863 sq. ft., two story (first story 2355 sq. ft., second story 508 sq. ft.) single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 365 sq. ft. of covered patio/porch and a 873 sq. ft. attached garage per the approved plans and any notations. Rescheck Energy Compliance. R-1CDA zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/23/20201/24/20201/24/2020APASS
DetailsJim Storey
Gotti Phone #: ###-####
DOC - Permit Finaled1/24/20201/24/20201/24/2020PPASS
DetailsJim Storey
BLD-Blower Door Test Results1/24/20201/24/20201/24/2020PDONE
DetailsJim Storey
Gotti Phone #: ###-#### 3.53
BLD-Energy code compliance10/31/201911/1/201911/1/2019APASS
DetailsMike Jordan
Gari Phone #: ###-####
BLD-Energy code compliance10/30/201910/31/201910/31/2019AFAIL
DetailsMike Jordan
Gari Phone #: ###-####. Needs to encapsulate wall insulation at vaulted ceiling in main living room.
BLD-Framing/Rough-in10/31/201910/31/201910/31/2019APASS
DetailsMike Jordan
Gari Phone #: ###-####
BLD-Framing/Rough-in10/28/201910/29/201910/29/2019AFAIL
DetailsMike Jordan
Gari Phone #: ###-####. Repair notched 2x10 for 2nd. floor at tub drain. Provide additional stud under T7 2 ply truss. Nail webs on 2ply T10 truss per the engineering. Fireblock furred walls at double top plates in hallway @main entry. Can not verify tempered glazing in bathroom. Foam under tub in masterbedroom and pex in bottom plate at master shower. Complete lateral bracing on M11 and M12 trusses. Corection notice posted. ok to insulate.
BLD-Wall Bracing10/1/201910/2/201910/2/2019APASS
DetailsMike Jordan
Shear // Gottie Phone #: ###-####
BLD-Foundation9/11/20199/12/20199/12/2019APASS
DetailsJim Storey
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru
BLD-Foundation9/11/20199/12/20199/11/2019PCANC
DetailsMike Jordan
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru Inspection cancelled via mobile web on Wednesday, September 11, 2019.
BLD-Footing9/10/20199/11/20199/11/2019APART
DetailsTell Riley
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru//setbacks ok per plans//WIP-still setting forms//discussed rebar he will get it in//