Permit for the construction of a new 2200 sq. ft., one story single family dwelling with 4 bedrooms, 3 bathrooms, approximately 277 sq. ft. of covered patio/porch and a 1207 sq. ft. attached garage per the approved plans and any notations. Prescriptive Energy Compliance. R-1CDA zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/28/20201/29/20201/29/2020APASS
DetailsJim Storey
Gaty- pplease call for access Phone #: ###-####
DOC - Permit Finaled1/29/20201/29/20201/29/2020PPASS
DetailsJim Storey
BLD-Blower Door Test Results1/29/20201/29/20201/29/2020PDONE
DetailsJim Storey
Gaty- pplease call for access Phone #: ###-#### 4.62
BLD-Energy code compliance11/12/201911/12/201911/12/2019PPASS
DetailsMike Jordan
Gari Phone #: ###-####
BLD-Framing/Rough-in11/12/201911/12/201911/12/2019PPASS
DetailsMike Jordan
Gari Phone #: ###-####
BLD-Framing/Rough-in11/8/201911/8/201911/8/2019PFAIL
DetailsBrandon Shaw
Hold downs not installed per manufacturers reccom...
BLD-Energy code compliance11/8/201911/8/201911/8/2019PFAIL
DetailsBrandon Shaw
Hold downs not installed per manufacturers reccom...
BLD-Framing/Rough-in11/5/201911/6/201911/6/2019PFAIL
DetailsMike Jordan
Gari Phone #: ###-####. Install h2.5 on E01 trusses. Install headers over doorway to bedroom #4 and at hallway entry(A01 interior bearing) Complete the install of hold downs for portal frame, west wall.
BLD-Framing/Rough-in11/4/201911/5/201911/5/2019ANR
DetailsMike Jordan
Gari Phone #: ###-####. Mech rough in inspection has failed.
BLD-Wall Bracing10/15/201910/15/201910/15/2019PPART
DetailsMike Jordan
shear // Gotti Phone #: ###-####. Ok to tyvek except for garage front.
BLD-Wall Bracing10/14/201910/14/201910/14/2019PFAIL
DetailsMike Jordan
Gari Phone #: ###-####. Install missing MSTC straps on exterior of RV bay opening. Install all missed blocking and nail. Provide engineering for fix on missing STDH-14 straps and bolts for hold downs.
BLD-Foundation9/19/20199/20/20199/20/2019APART
DetailsMike Jordan
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru
BLD-Footing9/18/20199/19/20199/19/2019APART
DetailsMike Jordan