Information based on query as of Monday, May 20, 2024.
Permit Information
Permit NumberBLD20-00422
StatusIssued
Name COASTAL CONSTRUCTION AND LUMBER COM
Site Address 11275 W GABRIELLE DR
Project NameGalahad Townhouses Sevenplex E
Customer NumberBLD20-00371,BLD20-00422-00427
ePlanReview 
Description
(SEVEN PERMITS FILED UNDER BLD20-00371) Permit for the construction of a new 1157 sq. ft., 2 story (first story 543 sq. ft., second story 614 sq. ft.) Townhouse with 2 bedrooms, 2.5 bathrooms, approximately 80 sq. ft. of covered patio/porch and a 0 sq. ft. attached garage per the approved plans and any notations. REscheck Energy Compliance. C-2D/DA zoning and setbacks per planning. ***RDP
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Energy code compliance8/10/20208/11/20208/11/2020APASS
DetailsMike Jordan
kenny *screened* Phone #: ###-####
BLD-Framing/Rough-in8/11/20208/11/20208/11/2020APASS
DetailsMike Jordan
kenny *screened* Phone #: ###-####
BLD-Energy code compliance8/7/20208/10/20208/10/2020ANR
DetailsMike Jordan
screened // Kenny Phone #: ###-####
BLD-Framing/Rough-in8/4/20208/5/20208/5/2020AFAIL
DetailsMike Jordan
SCREEENED // Kenny Phone #: ###-####. Complete lateral bracing on A02 trusses. Complete all fire caulking. Install all missed fasteners on fire wall and all missing pieces of sheet rock on firewalls. Pending mech. rough in inspection.
BLD-Wall Bracing7/16/20207/16/20207/16/2020PPASS
DetailsMike Jordan
Kenny *screened* Phone #: ###-####
BLD-Wall Bracing7/14/20207/14/20207/14/2020PNR
DetailsMike Jordan
Shear .... SCREENED // Kenny Phone #: 208- ###-####
BLD-Other7/7/20207/8/20207/8/2020APASS
DetailsMike Jordan
screened - firewall // Kenny Phone #: ###-####. 1st. floor base layers of 5/8 type x rock for firewalls.
BLD-Other7/6/20207/7/20207/7/2020ANR
DetailsMike Jordan
Fire wall- Kenny *screened* Phone #: ###-####
BLD-Foundation5/22/20205/26/20205/26/2020PPASS
DetailsMike Jordan
rebar // shane Phone #: ###-####. Interior thickend footings.
BLD-Foundation4/21/20204/21/20204/21/2020PCANC
DetailsMike Jordan
insulation // Kenny Phone #: ###-####
BLD-Energy code compliance4/21/20204/21/20204/21/2020PPASS
DetailsMike Jordan
insulation // Kenny Phone #: ###-####. rigid insulation at interior side of stemwall under slab on grade
BLD-Foundation4/16/20204/17/20204/17/2020PPART
DetailsMike Jordan
screened // Dane Phone #: ###-####
BLD-Footing4/15/20204/16/20204/16/2020PPASS
DetailsMike Jordan
Screened- Dane Phone #: ###-####