Information based on query as of Wednesday, May 1, 2024.
Permit Information
Permit NumberBLD20-01358
StatusIssued
Name CBH HOMES
Site Address 11110 W USTICK RD
Project Name15-1 Ustick Cottages
Customer Number01279EP & 01339-01341 & 01358-01361
ePlanReview 
Description
(8 GARAGES IN EPLAN UNDER BLD20-01279) Permit for a 264sq' garage attached to other garage(s) via a two-hour fire wall. Eaves permitted to cross property line per recorded plat. All work per plans, local codes and ordinances. Separate electrical permit required. **JAB**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Framing/Rough-in8/4/20208/4/20208/4/2020PPASS
DetailsTell Riley
truss repair document reviewed//putty pad added to recepticles per the super, fire cualk was used at wall penetrations//ok to cover//
BLD-Framing/Rough-in7/29/20207/30/20207/30/2020AFAIL
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Joel Hirtle***per Carl M. no rated exterior walls or soffits required due to common lots around all garages and the plat***

//provide truss engineering for trusses that appear to have been repaired in the field with gussets//low voltage ELE boxes for garage door sensors in the 2 hr wall, same stud bay will need to be protected per IRC 302.4.2//
//any through penetrations through the 2 hr walls need to be firestop protected in accordance with IRC R302.4.1.2//
BLD-Wall Bracing7/5/20207/6/20207/6/2020PPASS
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Joel Hirtle
BLD-Foundation6/7/20206/8/20206/8/2020APART
DetailsTell Riley
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo //measured setbacks from pins//need to adjust foundation to exact 2' setback on all sides//discussed with contact onsite and working on this when I left//hold downs and some forms still WIP//
BLD-Footing6/4/20206/5/20206/5/2020PPART
DetailsTell Riley
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo //WIP//pins set to measure 2' setback per the plat//met Ricardo and measured earlier today--crew will set strings at 2' setback for foundation inspection to confirm setbacks//
BLD-Footing6/1/20206/2/20206/1/2020ACANC
DetailsTell Riley
Phone #: 2086971241 >> Inspection requested via mobile web by heron